8.12.2
Electrical faults
Note
If you are operating the motor with a converter, the operating instructions of the converter must
also be observed if electrical faults occur.
Table 8-1
Electrical faults
↓ Motor fails to start
↓ Motor accelerates sluggishly
↓ Rumbling noise during startup
↓ Rumbling noise during operation
↓ High temperature rise during no-load operation
↓ High temperature rise with load
↓ High temperature rise of individual winding sections
Possible causes of faults
Remedial measures
X
X
X
X
Overload
Reduce the load.
X
Interrupted phase in the supply cable
Check the switches and cables.
X
X
X
X
Interrupted phase in the feeder cable af‐
ter switching on
Check the switches and cables.
X
Mains voltage too low, frequency too high Check the power supply conditions.
X
Mains voltage too high, frequency too low Check the power supply conditions.
X
X
X
X
X Stator winding incorrectly connected
Check the winding connection in the terminal box.
X
X
X
X Winding short circuit or phase short cir‐
cuit in stator winding
Determine the winding resistances and insulation
resistances. Carry out repair work after consulta‐
tion with the manufacturer.
X
Incorrect direction of rotation
Check the connection.
8.12.3
Mechanical faults
The following table shows the possible causes of and remedial measures for mechanical faults.
Table 8-2
Mechanical faults
↓ Grinding noise
↓ Overheating
↓ Radial vibrations
↓ Axial vibrations
Possible causes of faults
Remedial measures
X
Rotating parts are grinding
Establish the cause and realign the parts.
X
Rotor not balanced
Decouple the rotor and then rebalance it.
X
Rotor out of true, shaft bent
Contact the Service Center.
Operation
8.12 faults
SIMOTICS FD 1MH1
Operating Instructions 08/2017
129
Содержание SIMOTICS FD 1LL1
Страница 2: ...18 08 2017 17 24 V10 00 ...
Страница 32: ...Description 3 1 Comparison of IEC and GOST standards SIMOTICS FD 1MH1 32 Operating Instructions 08 2017 ...
Страница 58: ...Preparations for use 4 19 Converter operation SIMOTICS FD 1MH1 58 Operating Instructions 08 2017 ...
Страница 104: ...Electrical connection 6 6 Connecting the auxiliary circuits SIMOTICS FD 1MH1 104 Operating Instructions 08 2017 ...
Страница 120: ...Start up 7 10 Setting the motor parameters at the converter SIMOTICS FD 1MH1 120 Operating Instructions 08 2017 ...
Страница 176: ...Disposal 11 4 Disposal of components SIMOTICS FD 1MH1 176 Operating Instructions 08 2017 ...
Страница 178: ...Service and Support SIMOTICS FD 1MH1 178 Operating Instructions 08 2017 ...
Страница 182: ...Quality documents SIMOTICS FD 1MH1 182 Operating Instructions 08 2017 ...
Страница 187: ......