Communication
2.2 PROFINET communication
SIMOCODE pro - Communication
80
Function Manual, 11/2018, A5E40508495002A/RS-AC/003
Function blocks for SIMATIC S7
The application description "Saving Energy with SIMATIC S7 and ET200 S"
http://support.automation.siemens.com/WW/view/en/41986454
), which also contains an
example program for using PROFIenergy functions, is available on the Internet service portal
of Siemens AG, Industry Automation and Drives Technologies. You can also make use of
the blocks from the example to implement PROFIenergy functions in conjunction with
SIMOCODE pro V PN (GP).
In the application description in Chapter 4.2 "FB 815 PE_START_END functionality," you will
find the description of the block with which the "PE_START_Pause" or "PE_END_Pause"
commands can be directly transferred to an IO device.
With the FB 815 "PE_START_END" function block, you can transfer the "START_Pause" or
"END_Pause" commands directly to SIMOCODE pro V PN (GP).
For use of further functions, in Chapter 4.3 "FB 816 PE_CMD functionality" you will find a
universal function block with which you can transfer further commands of the PROFIenergy
profile (e.g. Query_Modes, PEM_Status, PE_Identify, Query_Measurement).
You will also find the structure of the command and response data of the FB 816 in Chapter
4.4 "Response Data" of the application description "Saving Energy with SIMATIC S7 and
ET200 S."