Installation guide
3.5 Standalone TIM 4 with an S7-400 or PC
SINAUT ST7 station control system
114
System Manual, 09/2016, C79000-G8976-C178-10
CPU type
As of article number
Minimum product version / firm-
ware version
CPU 417-4H
1)
6ES7 417-4HL00-0AB0
6ES7 417-4HL01-0AB0
6ES7 417-4HL04-0AB0
6ES7 417-4HL07-0AB0
1 / V2.1.0
1 / V2.1.0
V4.0.10
V4.5.0
CPU 417-5H PN/DP
1)
6ES7 417-5HT06-0AB0
V6.0
1)
Fault-tolerant SINAUT solutions with a CPU 414-4H or CPU 417-4H are not possible!
Note
A TIM 4 can be connected not only to a S7-400-CPU over its MPI port, but in principle with
every S7-300 CPU, in other words, also with the CPU types 317, 318 and 319 and with the
CPU 315-2 PN/DP with which a TIM 4 cannot be installed as a CP in the S7-300 rack.
S7-400 with one WAN attachment
The following figure shows the simplest configuration for an S7-400 with one connection to a
WAN over a TIM 4.
Figure 3-18 SIMATIC S7-400 with TIM 4 on MPI bus, 1 connection a WAN
A suitable modem or other transmission device can be connected to the combined RS-
232/RS-485 interface of the TIM 4.