Installation guide
3.5 Standalone TIM 4 with an S7-400 or PC
SINAUT ST7 station control system
System Manual, 09/2016, C79000-G8976-C178-10
117
Example of configurations with the SINAUT ST7cc or ST7sc control center systems
The SINAUT ST7cc control center system based on WinCC or the SCADA Connect
Software SINAUT ST7sc is connected to the SINAUT telecontrol network just as with an S7-
400 over one or more TIM 4 modules. These TIMs are connected to the MPI adapter of the
SINAUT ST7cc / ST7sc system over their MPI interface. The inclusion of a telecontrol
master, for example an S7-400 is not necessary. Data exchange with the stations is handled
by the master TIM 4 modules.
The following figure shows the simplest configuration for a SINAUT ST7cc or ST7sc control
center system with one (1) connection to a WAN.
Figure 3-21 SINAUT ST7cc / ST7sc control center systems with TIM 4 on MPI bus,
1 connection to WAN via MDx modem
In much the same way as with an S7-400, ST7cc / ST7sc can also have two connections to
a WAN. The following figure shows the configuration.