Appendix
10.3
Installing and operating the external parameter memory
The external parameter memory is available as an accessory. It is located in a connector
cover and comprises a permanent, rewriteable memory (EEPROM). The connector cover
covers the two connections of the CLX in the enclosure rating IP 65. The cover is shown in
Two connection cables that are secured by means of conduit thread connections
supply the signals to the CLX.
The external parameter memory is available in different implementations:
10.3.1
Function
When it is started, the CLX is initialized with he data stored in its internal parameter set. If
this parameter set has been copied to an external memory, the device can be replaced
easily. The replacement device, therefore, does not have to be configured manually. Instead,
it accesses the external parameter memory automatically (assuming that the correct start
option has been selected). It then imports the parameter set to its RAM. This option is set
by default. The "Device Ready" and "Read Result" LEDs indicate whether the external
memory was accessed successfully. The CLX also outputs plain-text messages for trouble-
shooting purposes on the terminal interface.
Fig. 10-7:
External parameter memory, installed on the CLX
22
22
88.5
50
27
27
Order no.
Two Connection cables with
CLX
Length Connection
2 020 307
Two 15-pin D Sub HD plug connections,
(pin assignment identical to device connec-
tions)
Without
heater
3 m
CLX to AMV/S 60
AMV 30-071 and BMV 10
2 020 981
Two open cable ends
Without
heater
3 m
CLX to non-SICK Power pack, free wiring
2 020 308
One 9-pin D Sub cable connector and one
open cable end
Without
heater
3 m
CLX to BMS 20
2 021 689
Two 15-pin D Sub HD plug connections,
(pin assignment identical to device connec-
tions)
With
heater
3 m
CLX to AMV 100/200
Table 10-2: External parameter memory