Installation procedure (overview)
Reading pulses via switching input "Sensor 1" (default setting)
1.
Check the delivery to make sure that none of the components is missing.
2.
Mount the CLX at the reading station and align it with the object carrying the bar code.
3.
Mount the AMV/S 60 Connection Module.
4.
Connect the CLX to the AMV/S 60 Connection Module using the two cables
no. 2 020 302. Alternatively, connect the device to the AMV/S 60 via the external
parameter memory no. 2 020 307.
5.
Connect the reading pulse sensor to the "Sensor" switching input in the AMV/S 60.
6.
Connect the host to the host interface in the AMV/S 60.
Adapt the AMV/S 60 to the host interface type of the CLX.
7.
Switch on the power supply to the AMV/S 60.
The "Device Ready" LED lights up after the CLX has started.
CLX with external parameter memory connected:
The "Device Ready" LED and the "Read Result" LEDs blink after the CLX has started.
The CLX is
not
ready to start reading. See
step 11
.
8.
Switch on your PC and start Windows
TM
(minimum requirement: Windows 95
TM
).
9.
Install the "CLV-Setup" software, online CLV-Setup Help and, if necessary, the I-View-
Pro
TM
HTML browser on your PC.
10. Connect the PC to the terminal interface of the CLX. To do so, connect the RS 232 cable
(e. g. no. 2 014 054) to the "Service plug" in the AMV/S 60.
11. Start the "CLV-Setup" program.
CLV-Setup establishes communication with the CLX and uploads the parameter set.
The parameters are then displayed on the tabs.
CLX with external parameter memory connected:
First download the CLX parameter set to the external memory.
Disconnect the AMV/S 60 briefly from the power supply to restart the CLX.
12. Carry out a test read using test bar codes (clock the CLX accordingly).
Display the reading result in the Terminal Emulator window of the "CLV-Setup" program.
13. Configure the CLX for the application using the settings on the tabs in CLV-Setup. Copy
(download) the modified parameter set to the CLX temporarily.
Do
not
switch off the power to the AMV/S 60 (CLX)!
14. Test the application under realistic conditions.
15. Check whether the data is transmitted correctly between the CLX and host.
16. If necessary, correct and optimize the parameter values.
Copy (download) the parameter set
permanently
to the CLX.
CLX with external parameter memory connected:
Copy the modified parameter set to the external parameter memory.
17. Save the parameter set as a configuration file "*.scl" in the "CLV-Setup" program.
The CLX can then be operated with the
application-specific
settings.