Chapter
9
Operating Instructions
Compact OMNI Scanner
9-2
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 237/0000/07-05-2002
Technical data
9.2
Data sheet CLX 490-0011 Compact OMNI Scanner
Technical data as CLX 490-0010 with the following exceptions:
9.3
Dimensioned drawing of the CLX
Type
CLX 490-0011
Design
with heater
Switching on function/temperature graph
see
Chapter 10.4 Optional heating, Page 10-12
Power-on delay
35 ... 40 min (at 24 V DC and min. ambient operating temperature –30
°
C)
Operating voltage
24 V DC +20%/–10%
Power consumption
typically 75 W, max 90W
Required cross-section
min. 0.5 mm
2
(for power supply)
Weight
approx. 2 kg
Ambient operating/storage temperature
–30 ... +35
°
C/–20 ... +70
°
C
Table 9-2: Technical specifications of the CLX 490-0011
Fig. 9-1:
Dimensions of the CLX 490
10
10
10
38.5
12
56
21
113
33.5
43.2
78
114
142
152.6
175.5
114.7
208
CLX 490-0010
CLX 490-0011
Drilled hole, M 6,
7 mm deep
All values in mm
Blind hole thread,
∅
3.6 mm,
6 mm deep