Operating Instructions
Chapter
5
CLX 490
8 009 237/0000/07-05-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
5-1
Electrical installation
5
Electrical installation
5.1
Installation sequence
•
Connect the CLX to a SICK Connection Module from the series AMV/S, BMV/BMH 10
or BMS 20, or using a customer-specific wiring configuration
•
Connect the data and function interfaces of the CLX in the module
•
Connect the PC to the Connection Module (at the terminal interface on the CLX)
•
Connect the power supply to the Connection Module
5.1.1
SICK Connection Modules (overview)
CLX Type
Temperature
range
Connection
module
Purpose
see
chapter
CLX
without
heater
0 ... +40
°
C
AM
V
60
– Connecting
one
CLX
– Operating voltage 18 ... 30 V DC
– Enclosure rating IP 30, max. IP 54
AM
S
60
– Connecting
one
CLX
– Operating voltage 230 V AC (115 V)/24 V DC
– Enclosure rating IP 30, max. IP 54
AMV 100
– Connecting
one
CLX
– Operating voltage 18 ... 30 V DC
– Enclosure rating IP 52,
with connector cover max. IP 65
BMV/BMH 10
Profibus-DP
– Connecting
one
CLX to the Profibus-DP
– Operating voltage 20 ... 30 V DC
– Enclosure rating IP 52,
with connector cover max. IP 65
BMS 20
Interbus-S
– Connecting
one
CLX to the Interbus-S
– Operating voltage 24 V DC
– Enclosure rating max. IP 54
5.2.4
AMV 30-071
– Connecting
two
CLX
– Operating voltage 18 ... 30 V DC
– Enclosure rating IP 30, max. IP 54
AMV 200
– Connecting
two
CLX
– Operating voltage 18 ... 30 V DC
– Enclosure rating IP 52,
with connector cover max. IP 65
CLX
with
heater
–30 ... +35
°
C
AMV 100
– Connecting
one
CLX
– Operating voltage 24 V DC +20%/–10%
– Enclosure rating IP 52,
with connector cover max. IP 65
AMV 200
– Connecting
two
CLX
– Operating voltage 24 V DC +20%/–10%
– Enclosure rating IP 52,
with connector cover max. IP 65
Table 5-1: Connection Modules for the CLX