Chapter
6
Operating Instructions
Compact OMNI Scanner
6-6
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 237/0000/07-05-2002
Operation
Transfering and saving a complete CLX parameter set (download)
1.
Click
in the toolbar.
The "Device Ready" LED is extinguished.
CLV-Setup copies the parameter set to the RAM of the CLX. The D
OWNLOAD
PARAMETERS
dialog box with the storage options is then displayed.
P
ERMANENT
: CLV-Setup copies the parameter record to the RAM and to the EEPROM of
the CLX.
T
EMPORARY
: CLV-Setup copies the parameter record to the RAM only. The changes are
lost when the CLX supply voltage is switched off.
2.
Confirm the dialog box with the desired storage option.
The "Device Ready" LED lights up again.
The new parameter set is stored in the CLX either permanently or temporarily.
CLX with external parameter memory
If the parameter set was downloaded and stored
permanently
, CLV-Setup opens a further
dialog box for adjusting the parameter set in the external memory, if the start option is set
to S
TART
WITH
EXTERNAL
PARAMETERS
.
¾
Choose the C
OPY
NOW
INTERNAL
PARAMETER
SET
TO
EXTERNAL
MEMORY
option.
CLV-Setup then instructs the CLX to copy the new parameter set to the external
memory. The "Device Ready" LED lights up again.
The internal and external parameter sets are now identical.
Chapter 10.3.5 Adjusting the parameter set in the external parameter memory af-
ter it has been downloaded to the CLX, Page 10-10
Saving a parameter set in CLV-Setup
1.
To save the modified parameter set as a new configuration file in CLV-Setup, or to over-
write an existing file, choose F
ILE
and S
AVE
AS
.
The CLX F
ILE
SELECTOR
dialog box is then displayed.
2.
Enter the file name in the dialog box (file name extension "*.scl") and confirm the entry.
The new parameter set is now stored in CLV-Setup in the subdirectory "data".
6.4.2
Function of the tabs in CLV-Setup (overview)
Reading Configuration
This tab and further dialog boxes are used to set the following:
•
Scanning frequency
•
Start/stop ratio
•
Autofocus mode (distance measurement, preference focus distance, delay of focus
chance, depth of field optimization, autofocus space)
•
Reading distance configuration for event-controlled focus control (focus position,
assignment table)
•
Trigger source for the focus control (if event-controlled)
•
Adjustment to bar code characteristics