Operation
6.5.4
Displaying and editing operating data
This function enables statistical operating data, which the CLX maintains in the form of coun-
ters during the reading procedure, to be displayed and reset.
The CLX does not output a reading result in this mode.
1.
Click
in the tool bar.
The CLX cancels the Reading mode and the "Device Ready" LED is extinguished. The
O
PERATING
D
ATA
dialog box appears (
2.
After checking/resetting the desired counters, click OK to confirm any changes made.
The CLX then returns to the Reading mode and the "Device Ready" LED lights up.
6.5.5
Reading diagnosis
Function of the
terminal interface
. In this mode, the CLX outputs the data contents of all
the bar codes that were read – including those that, according to the evaluation criteria,
were not read properly and were thus incorrect – together with the associated reading dia-
gnosis data via the terminal interface. The number of bar codes output can, therefore, be
higher than the number of those that were sent via the host interface in the reading result.
In the default setting, this mode is selected for the terminal interface.
shows the output format of the terminal interface.
In the default setting, the CLX only outputs the error status ST in the separator via the host
interface.
Fig. 6-8:
CLV-Setup: "Operating Data" dialog box