Chapter
6
Operating Instructions
Compact OMNI Scanner
6-14
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 237/0000/07-05-2002
Operation
Fig. 6-2:
CLV-Setup: Displaying the reading result in the Terminal Emulator
Fig. 6-3:
Reading result of the terminal interface: structure for Good Read
Good Read:
TT=_ _200 ms MG=_57 % n=_1 AK=1
0123412345
C39 100% St=0 CL=10 CP=_9
CD=_756 CS=_13 CA=_13 CK=_13 DI=X
PO=·_279 OW=+_ _0 FC=_712 CX=_597 CY=_69
CZ=855 ON=__0
With:
1st. line:
TT
=
Duration of the reading interval
MG
=
Temporal mean value of the identification quality
n
=
Number of detected bar codes
AK
=
No. of the used distance configuration
1)
2nd. line:
0123412345= Data contents of the bar code
3rd. line:
C39
=
ID: Code type Code 39
_99%
=
Identification quality
ST
=
Read status (ST = 0: Good Read)
CP
=
Code position
CL
=
Code length (number of characters)
CA
=
Scan effort
CS
=
Code reliability
CK
=
Code continuity
DI
=
Decoding direction
(F = in scanning direction, R = against scanning direction)
4th line
PO
=
exact code position (3-digit for tracking)
OW
=
Exact oscillating angle (3-digit for tracking)
FC
=
Current focus position (4-digit for tracking)
CX
=
X-coordinate of bar code (for OTS in transport direction)
CY
=
Y-coordinate of bar code
(for OTS across to transport direction)
CZ
=
Z-coordinate of bar code (for OTS from above directly)
ON
=
Object number (for tracking)
1)
not relevant for autofocus function