PN-L803C/80TC3 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 22
12-4. SYSTEM LOGS AND TAB
Logs are displayed with list format downside. Each item’s
meanings are below.
LOG’S MEANING
Header
Meaning and remark
ID
The smaller the number, the newer
the log data.
Use [ID] to line up in the order of
operation.
Date
It displays date and time when
operation occurred. The icon is
displayed on left edge to stand out, if
“Kind” is “Abnormal State”.
Time elapsed from
Power Supply
It displays the operation time. (The
time after turning on the power of the
monitor.)
Kind
It displays the kind of log. Detail
information is described in “Log
Kind”.
Input
If “Kind” is “Operation” or “Abnormal
State”, it displays the input source of
main screen. If “Kind” is “Change
Signal”, it displays the input source
which signal is changed and displays
which screen (Main or Sub)’s signal
is changed in parenthesis. If “Kind” is
“Power Off Reason”, it displays
none.
Information
It displays information depending on
“Kind”.
Detail information is described in
“Log Kind”.
Parameter 1/2
It displays parameter. Detail
information is not open.
LOG KIND
Header
Meaning and remark
Abnormal
State
Log
It displays the log about abnormal
state, for example “Temperature
error”. Abnormal kind is
displayed in “Information”.
Change
Power
State Log
It displays the log of power off. The
reason of power change is
displayed in “Information”.
Change
Signal
Log
It displays the log changing signal.
The timing of new signal is
displayed in “Information” as
“[Width] x [Height] @ [Refresh
rate]” or “No Signal”.
Header
Meaning and remark
Operation with IR
Remote/Key
It displays the log of
operations with IR remote
or button on body.
Operation record is
displayed in “Information”.
Operation by
RS-232C
(
Operation
)
It displays the log of
operation by RS-232C
command. The command
is displayed in
“Information”.
Extended Operation
by RS-232C
(Operation)
The sent command is
displayed in “Information”.
Operation by
Browser(Operation)
It displays the log of
operation by browser. The
command the occurred by
operation
(RS-223C/LAN command)
is displayed in
“Information”
Extended Operation
by Browser
(
Operation
)
Other Operation
(
Operation
)
It displays the log of
operation except above,
for example, power off by
schedule timer. Operation
kind is displayed in
“Information”.
Developer Info
It displays the Information
for the developer.
Содержание PN-80TC3
Страница 150: ...PN L803C 80TC3 DISASSEMBLY AND ASSEMBLY 6 6 3 Remove the four screws M3x6 SW W Then remove LED Power Supply PWB ...
Страница 183: ...PN L803C 80TC3 TROUBLESHOOTING 7 10 FUSE POSITION MAIN PWB F2200 F2300 F2102 F2302 F2101 ...
Страница 184: ...PN L803C 80TC3 TROUBLESHOOTING 7 11 5V POWER SUPPLY PWB F2100 F2100 ...
Страница 191: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 7 3 BLOCK DIAGRAM Block diagram ...
Страница 202: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 18 5 PARTS LAYOUT Main PWB TOP ...
Страница 203: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 19 BOTTOM ...
Страница 204: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 20 LED Power Supply PWB TOP ...
Страница 205: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 21 BOTTOM ...
Страница 206: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 22 Key PWB TOP BOTTOM ...
Страница 208: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 24 5V Power Supply PWB connector Upper pin 5V Output Lower pin GND ...