PN-L803C/80TC3 INSTALLATION, ADJUSTMENT, SETTING, OPERATION 2 - 32
(MEMO)
- Up to 8 SCHEDULE items can be registered.
- Setting the SCHEDULE flashes the power LED alternately in red and orange in standby mode.
- A SCHEDULE that has a large number has precedence over that of a small number when schedules overlap.
- When START INPUT MODE is set to WHITEBOARD, the screen that appears when the power on schedule is executed is WHITEBOARD
regardless of the INPUT setting.
- When executing a power off schedule, if there is unsaved data on the WHITEBOARD, a data save message will appear about once a
minute starting about 5 minutes prior to power off. Save data you need. When the power turns off, the data will be lost.
3 - 2.INITIALIZATION (RESET)/FUNCTIONAL RESTRICTION SETTING (FUNCTION)
You can return the settings to their factory-preset values and restrict operations.
1. Hold down until “F” appears in the upper left corner of the screen.
2. While “F” appears, press in that order.
3. Select and set the items.
ALL RESET
Resets the settings to the factory default settings.
Press , select the resetting method, and then press .
After initialization, turn the main power switch off and then back on.
ALL RESET1.....Resets all the settings to the factory default settings.
ALL RESET2.....Returns all settings to the factory default settings except for the following items:
LAN SETUP, RS-232C/LAN SELECT, BAUD RATE, NETWORK, MAIL, SERVICE &
SUPPORT, and SNMP
ADJUSTMENT
LOCK
You can disable operations on the monitor and the remote control unit that use buttons.
OFF....Enables operation.
ON 1...Disables all operations other than turning power on/off and FUNCTION.
ON 2...Only the FUNCTION operation is enabled.
Disables all operations other than FUNCTION (not even power on/off).
When STANDBY MODE is set to LOW POWER, ON 2 cannot be set.
ADJUSTMENT
LOCK TARGET
Sets the target to prohibit operation of with ADJUSTMENT LOCK.
REMOTE CONTROL...... Prohibits remote control operation
MONITOR BUTTONS.... Prohibits monitor button operation
BOTH.............................. Prohibits remote control and monitor button operation
RS-232C/LAN
Specifies whether to allow control via RS-232C or LAN.
OSD DISPLAY
Shows/hides the menu, modes and messages.
The FUNCTION screen cannot be hidden.
ON 1............... Shows all menus, modes and messages.
ON 2............... Hides messages automatically displayed by the display. Shows messages during operation.
OFF................ Hides all menus, modes and messages.
LED
Specifies whether to light the power LED.
TEMPERATURE
ALERT
Selects the notification method for an abnormal temperature.
OFF............... Do not notify about an abnormal temperature.
OSD & LED... When an abnormal temperature is detected, the power LED flashes in red and green
alternately and the screen displays a message: TEMPERATURE.
LED............... When an abnormal temperature is detected, the power LED flashes in redand green
alternately.
STATUS ALERT
Selects the notification method for a hardware error.
Содержание PN-80TC3
Страница 150: ...PN L803C 80TC3 DISASSEMBLY AND ASSEMBLY 6 6 3 Remove the four screws M3x6 SW W Then remove LED Power Supply PWB ...
Страница 183: ...PN L803C 80TC3 TROUBLESHOOTING 7 10 FUSE POSITION MAIN PWB F2200 F2300 F2102 F2302 F2101 ...
Страница 184: ...PN L803C 80TC3 TROUBLESHOOTING 7 11 5V POWER SUPPLY PWB F2100 F2100 ...
Страница 191: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 7 3 BLOCK DIAGRAM Block diagram ...
Страница 202: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 18 5 PARTS LAYOUT Main PWB TOP ...
Страница 203: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 19 BOTTOM ...
Страница 204: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 20 LED Power Supply PWB TOP ...
Страница 205: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 21 BOTTOM ...
Страница 206: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 22 Key PWB TOP BOTTOM ...
Страница 208: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 24 5V Power Supply PWB connector Upper pin 5V Output Lower pin GND ...