PN-L803C/80TC3 IMPORTANT INFORMATION FOR SERVICING THE DISPLAY 3-1
CHAPTER 3. IMPORTANT INFORMATION FOR SERVICING THE DISPLAY
1. MAIN PWB, LCD MODULE UNIT, T-CON PWB, TOUCH PANEL UNIT REPLACEMENT
PROCEDURES
The following information as well as user setting information are saved to the EEPROM (IC1701) controlled by main firmware and
EEPROM(IC2000) controlled by sub micon firmware.
<INFORMATION STORED IN THE EEPROM’S (IC1701) CONTROLLED BY THE MAIN FIRMWARE.>
・
MODEL NAME
・
SERIAL NUMBER
・
USAGE TIME
*1
・
WHITE BALANCE SETTING VALUE
*1
・
GAMMA SETTING VALUE
・
CALIBRATION SETTING VALUE
・
SYSTEM LOG
*1 This information is linked with the LCD module.
<INFORMATION STORED IN THE EEPROM (IC2000) CONTROLLED BY THE LAN MICROCONTROLLER
FIRMWARE.>
MAC ADDRESS
Therefore, when Main PWB and the LCD Module Unit are replaced, initialization and setting must be performed according to necessity.
Then, after finishing the replacement, perform “ALL RESET”.
1-1. INFORMATION ITEMS
MODEL NAME
The machine has model name which is described on the nameplate at the back of the machine.
SERIAL NUMBER
The machine has its own serial number which is described on the nameplate at the back of the machine.
→
Refer to “6-3.SERIAL NUMBER SETTING FUNCTION”
→
Refer to “12.SERIAL NUMBER WRITING PROCEDURES
USAGE TIME
This information is linked with the LCD module unit. When replacing the Main PWB, read the information
before replacement, and write it to the new Main PWB after replacement. It is necessary to initialize this
setting when the LCD module unit is replaced.
→
Refer to “6-4. USAGE TIME SETTING FUNCTION
→
Refer to “9. USAGE TIME SETTING PROCEDURE”
WHITE BALANCE
SETTING VALUE
This information is linked with the LCD module unit. When replacing the Main PWB, read the information
before replacement, and write it to the new Main PWB after replacement. Execute resetting when the LCD
module unit is replaced.
→
Refer to “14. WHITE BALANCE SETTING PROCEDURE BY OSD”
GAMMA
SETTING VALUE
This value is linked with the LCD module unit. When replacing the Main PWB, read this value before
replacement and write it into the Main PWB after replacement. When replacing the LCD module unit, reset
this value.
→
Refer to “16. GAMMA SETTING PROCEDURESWITH THE OSD”
CALIBRATION
SETTING VALUE
Since a service part Main PWB has been adjusted, there is no need to set when replacing the Main PWB.
Setting may be required depending on the replaced part.
→
Refer to “3. CALIBRATION
”
SYSTEM LOG
INFORMATION
This information is included in user operation and system information.
→
Refer to “ 12.OPERATING MANUAL OF THE LOG TOOL“
MAC ADDRESS
The MAC address is the unique ID number assigned to the Main PWB for LAN communication.
The unique ID number is written into the Main PWB (service part).
Содержание PN-80TC3
Страница 150: ...PN L803C 80TC3 DISASSEMBLY AND ASSEMBLY 6 6 3 Remove the four screws M3x6 SW W Then remove LED Power Supply PWB ...
Страница 183: ...PN L803C 80TC3 TROUBLESHOOTING 7 10 FUSE POSITION MAIN PWB F2200 F2300 F2102 F2302 F2101 ...
Страница 184: ...PN L803C 80TC3 TROUBLESHOOTING 7 11 5V POWER SUPPLY PWB F2100 F2100 ...
Страница 191: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 7 3 BLOCK DIAGRAM Block diagram ...
Страница 202: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 18 5 PARTS LAYOUT Main PWB TOP ...
Страница 203: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 19 BOTTOM ...
Страница 204: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 20 LED Power Supply PWB TOP ...
Страница 205: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 21 BOTTOM ...
Страница 206: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 22 Key PWB TOP BOTTOM ...
Страница 208: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 24 5V Power Supply PWB connector Upper pin 5V Output Lower pin GND ...