PN-L803C/80TC3 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 6
5 – 3. METHOD3
Check with the “STATUS[XXXX]” number.
1) When an error occurs, four-digit figures are displayed after the
message of “STATUS” on the left lower section of the screen.
They are assigned as follows.
Bit
PN-L703A
0 SYSTEM
POWER1
1 SYSTEM
POWER2
2 SYSTEM
POWER3
3 SYSTEM
POWER4
4 SYSTEM
POWER5
5 BACKLIGHT
6 TOUCH
PANEL
7 - 10
Reserved
11
Low voltage abnormality
12 - 13
Reserved
14
Temperature sensor abnormality
15 Temperature
abnormality
5 – 4. METHOD4
Check with the item of “STATUS” on the “Product information
(INFORMATION)” screen.
When [DISPLAY] button is pressed, the “INFORMATION” screen
is displayed.
Check with the “STATUS” item on the screen.1) When an error
occurs, four-digit figures are displayed after the message of
“STATUS” on the left lower section of the screen. They are
assigned as follows.
A
Hardware monitoring result
The error detection position is
displayed with the same number
as the “METHOD 3”.
B
The number of controls of
the backlight when a
temperature abnormality
occurs
Displayed in 2 digits.
For more than 99 times, “99” is
displayed.
C
Accumulated control time of
the backlight when a
temperature abnormality
occurs
Displayed in 2 digits.
For more than 99 hours, “99” is
displayed.
D
Number of shifts to the
power standby state when a
temperature abnormality
occurs
Displayed in 2 digits.
For more than 99 times, “99” is
displayed.
E
Reserved
(Not used for this time)
F
Reserved
(Not used for this time)
It takes some time necessary for judgment of a temperature
abnormality and a hardware abnormality as shown below:
- Temperature abnormality:
Min. 2 minutes (Exceeding the threshold value 3 times
continuously in the interval of 1 minute).
- Hardware abnormality:
Min. 18 seconds (Exceeding the threshold value 4 times
continuously in the interval of 6 seconds).
Though, therefore, the threshold value is exceeded on the
“HARDWARE CHECK” screen of SERVICE MANU 2 or in the
periodic send/ test mail, “OK” may be displayed.
In addition, when “NG” judgment is made once, “NG” state is
maintained until the power is turned OFF/ON. Even if, therefore,
the target value is reduced below the threshold value, the
judgment may be “NG” with a normal value.
INFORMATION1
INPUT MODE
SIZE
COLOR MODE
BRIGHT
VOLUME
ID No.
MODEL
S/N
1920x1080 V:999Hz H:999.9kHz
STATUS
XXXX-XXXX-XXXX-XXXX
TOUCH PANEL
LAN
Содержание PN-80TC3
Страница 150: ...PN L803C 80TC3 DISASSEMBLY AND ASSEMBLY 6 6 3 Remove the four screws M3x6 SW W Then remove LED Power Supply PWB ...
Страница 183: ...PN L803C 80TC3 TROUBLESHOOTING 7 10 FUSE POSITION MAIN PWB F2200 F2300 F2102 F2302 F2101 ...
Страница 184: ...PN L803C 80TC3 TROUBLESHOOTING 7 11 5V POWER SUPPLY PWB F2100 F2100 ...
Страница 191: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 7 3 BLOCK DIAGRAM Block diagram ...
Страница 202: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 18 5 PARTS LAYOUT Main PWB TOP ...
Страница 203: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 19 BOTTOM ...
Страница 204: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 20 LED Power Supply PWB TOP ...
Страница 205: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 21 BOTTOM ...
Страница 206: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 22 Key PWB TOP BOTTOM ...
Страница 208: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 24 5V Power Supply PWB connector Upper pin 5V Output Lower pin GND ...