![background image](http://html.mh-extra.com/html/sharp/iv-s20/iv-s20_user-manual_367258062.webp)
3-41
3
Operation Examples (Point measurement)
2
2
3
4
5
6
1
POINT SIZE
Y-08
×
X-08(2~32)
2
STO PNT POSITIONS 000(0~255) REG.NO
YES
3
START POINT POS MOVE(
,
)
4
BLOCK LAYOUT
001
×
001
5
BLOCK SPACING
X-004
Y-004
6
STORE BLOCK COND EXEC
7
DELETE BLOCK COND EXEC
8
UPPER MENU
P001
P000
P002
P003
P005
P004
P006
(Point No. registration)
[EVALUATION COND] (TYPE00-MEAS1-POINT MEAS)
1
CHG PAGE TEST RUN [TEST RESULT ]
[OUT]
2
P000 :
WH
OK
NO
3
P001 :
WH
OK
NO
4
P002 :
WH
OK
NO
5
P003 :
WH
OK
NO
6
P004 :
WH
OK
NO
7
P005 :
WH
OK
NO
8
P006 :
WH
OK
NO
9
P007 :
0
MAKE A TEST RUN (SET KEY)
q
UPPER MENU
1
2
3
3
4
Continued from the preceding page
(6) Operation for point setting
1. Press the ESC key, and all of the menus to be used for point setting will be displayed.
2. Move the cursor to
2
STO PNT POSITIONS (point registration, individual) with the up and
down keys, and press the SET key. Move the cursor to YES with the left and right keys, and
press the SET key.
-
The window (8 pixels x 8 pixels) for point No. 000 will start blinking.
3. Move the cursor to
3
START POINT POS (point position, starting) with the up and down
keys, and press the SET key.
4. Move the window for point No. P000 to the desired position in the object and press the SET
key.
-
The binary image will be displayed in the window according to the conditions set in item (5).
5. Move the cursor to
2
STO PNT POSITIONS (point registration, individual) with the up and
down keys, and press the SET key. Enter the number "001" with the up key. Move the cursor
to "YES" with the right key, and press the SET key.
- Move the window for point No. P001 the same as in steps 3 and 4, and press the SET key.
- Create windows for point Nos. P002 to P006 the same way.
6. Move the cursor to
8
UPPER MENU with the up and down keys, and press the SET key.
-
The screen will return to [MEASURING COND] (measurement condition) menu.
7. On the [MEASURING COND] menu, move the cursor to
5
UPPER MENU with the up and
down keys, and press the SET key.
-
The screen will return to the [TYPE00-MEAS1] (type: 00, measurement: 1) menu.
8. On the [TYPE00-MEAS1] menu, move the cursor to
7
EVALUATION COND (evaluation
condition) with the up and down keys, and press the SET key.
-
The [EVALUATION COND] menu will be displayed.
(7) Operation on the [EVALUATION COND] (evaluation condition) menu
1. Move the cursor to
2
P000 with the up and down keys, and press the SET key.
2. Select WH (white) with the up and down keys, and press the SET key.
- Specify WH (white) for point No. P001 to P006 the same as in steps 1 and 2.
- In this operation, the images (binary images) in the windows at point No. P000 to P006 are
checked to see if they are white or black. If they are all white, the program can decide that
the object exists.
3. Move the cursor to
0
MAKE A TEST RUN with the up and down keys, and press the SET
key. A test will be executed, and the test result (OK/NG) will be displayed.
Continued on the following page