3-3
3
Operation Examples (Area measurement by binary conversion)
1
3
2
[
TYPE00-MEAS1
]
1
MEAS SELECTION NO
CHECK-DEG-OF-MATCH
DST&AGL MES. (GRAY&EDGE GRAV)
INSPECT-LEAD MEASR-BIN-AREA
CNT-BIN-OBJ LABEL-BIN-OBJ
POINT MEAS
3
SELECT CAMERA CAM1
CAM2
4
COPY
EXEC
←
TYPE00
−
MEAS1
−
NO
5
INITIALIZATION
EXEC
6
MEAS.PROG. COND (TO NEXT SUB-MENU)
7
EVALUATION COND (TO NEXT SUB-MENU)
8
NUMERIC CALC COND (TO NEXT SUB-MENU)
9
OUTPUT CONDITIONS (TO NEXT SUB-MENU)
0
UPPER MENU
1
[OBJECT TYPE COND]
1
OBJECT TYPE NO.
00(0~15)
2
EDIT
COPY(
←OBJ
TYPE00) INITIALIZE
3
TITLE REGISTRATION (TO NEXT SUB-MENU)
4
MEAS.0, CAMERA1
NO (TO NEXT SUB-MENU)
5
POS. ADJ.CAMERA1
NO ADJ. [REG. 0-1PNTSXY
]
6
MEAS.0, CAMERA2
NO (TO NEXT SUB-MENU)
7
POS. ADJ.CAMERA2
NO ADJ. [REG. 0-1PNTSXY
]
8
SELECT CAMERA IMG NO CAM1 CAM1 CAM1&2
0
MEASUREMENT 1
NO (TO NEXT SUB-MENU)
q
MEASUREMENT 2
NO (TO NEXT SUB-MENU)
w
MEASUREMENT 3
NO (TO NEXT SUB-MENU)
e
FINAL CALC RESULT
(TO NEXT SUB-MENU)
r
FINAL OUTPUT COND (TO NEXT SUB-MENU)
t
SYSTEM-IN/OUT
(TO NEXT SUB-MENU)
y
HALT MEAS ON NG
NO
YES
u
UPPER MENU
F C1 H
1
3
2
[MEASURING COND] (TYPE00-MEAS.1-MEAS-BIN-AREA)
1
REGST NO.
00(0~15)
REG.NO
YES
2
BINARY AREA COND (TO NEXT SUB-MENU)
3
UPPER MENU
Continued from the preceding page
(3) Operation on the [OBJECT TYPE COND] menu
1. Move the cursor to
0
MEASUREMENT 1 and press the SET key.
-
The [TYPE00-MEAS1] (type: 00, measurement: 1) menu will be displayed.
(4) Operation on the [TYPE00-MEAS1] menu
1. Move the cursor to
1
MEAS SELECTION (select measurement) and press the SET key.
2. Move the cursor to MEASR-BIN-AREA (area measurement by binary conversion) and press
the SET key.
3. Move the cursor to
6
MEAS.PROG. COND (conditions of measurement program) and press
the SET key.
-
The [MEASURING COND] (measurement condition) menu will be displayed.
(5) Operation on the [MEASURING COND] menu
1. Move the cursor to
1
REGST NO. (register number) and press the SET key.
2. Move the cursor to YES, and press the SET key.
-
Item
2
will be highlighted.
3. Move the cursor to
2
BINARY AREA COND (condition for measurement window) with the
up and down keys, and press the SET key.
-
The [BIN.AREA SET] (binary zone setting) menu and a measurement window will be
displayed.
Continued on the following page