11-9
11
Setting the Input/Output Conditions
[I/O SETTINGS]
1
MEAS TRIG INP I/F PARALLEL SERIAL CCD-TRIG
2
START CCD SAMPLE AUTO(EDGE LEVL) PARALEL SERIAL
3
SERIAL OUTPUT NO PC-LINK SERIAL
(CCD SAMPLING
=PARALLEL
)
8
SERIAL CONDITIONS (TO NEXT SUB-MENU)
9
COMPUTER LINK (TO NEXT SUB-MENU)
· Setting order
1
→
2
→
3
→
8
→
9
Programmable
controller
· Configuration example
Data
(Computer link)
Settings listed in section 11-3 “CCD trigger”
Start sampling
input X0
Object type change
(paralell I/F)
IV-S20 main
housing
Power supply
(24 VDC)
Monitor
Camera 1 (image cap CCD trigger)
Camera 2 (image capturing)
Remote keypad
(6) Measurement start input = CCD trigger, start sampling = parallel, object type change =
parallel, result output = computer link/parallel
When the start sampling input (X0) is turned ON, the CCD trigger is enabled. (Sampling starts)
Note 1: When the settings listed in section 11-3 "CCD trigger" have not been made, a
CCD TRIGGER NOT SET. (error 34) will occur.
Note 2: Start sampling input (X0)
1. Sampling will be performed while this input terminal is ON. When it is turned
OFF, the sampling will stop.
During sampling,
will flash in the upper right corner of the MAIN OPS MENU.
2. After the measurement is terminated, the sampling will be restarted when the
X0 terminal is changed from OFF to ON.
· Time chart
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
Result output
Result output
Result
output
Result
output
Measurement
start input
(X0)
CCD trigger
cycle
Computer link
Start accd sampling by turning ON
measurement start input (X0).
BUSY signal is turned OFF
at the clusion of
the result output.
Start accd sampling
by turning OFF
measurement start
input (X0).
CCD trigger
window
(not highlighted)
Object type
number input
(X1 to X4)
Specified object type number
Black
White
Trigger
Trigger
Black
BUSY output
Terminate
measurement
(C119)
Measurement result is valid at the
end of a measurement
PC calculation
condition
Halt PC operation
during measurement
Halt PC operation
during measurement
When the object type is changed,
all Y output and auxiliary relays
turn OFF.
Parallel output is valid for PC control after
the measurement result is determined.
Parallel output
(Y0 to Y7)