10-12
PC Function
10
Kind of
output
signal
External
output
instructions
Counter
instructions
Y0 to Y7
Y8 to Y15
TM0 to TM7
Deletion
The output relay on the row where the cursor is located will be deleted.
· See page 10-7 for details about the auxiliary relays C000 to C127.
Function
Data
memory
No.
Output to the parallel I/F, general purpose serial I/F and computer link
Output to the general purpose serial I/F or computer link
A timer terminal will be turned ON for a set amount of time (set value
000 to 999, unit 10 ms) after the timer instruction is input.
(Decrementing type)
When the timer instruction input is turned OFF, the timer terminal will
be turned OFF.
CN0 to CN7
While the counter reset relay is OFF, if a counter instruction input is
cycled from OFF to ON, the number of times you set (set value 000
to 999), the counter terminal will be turned ON. (Decrementing type)
When the counter reset relay is turned ON, the counter terminal is
turned OFF.
Create a circuit to turn the counter reset relay ON and OFF on the
row following a row that containing a counter instruction.
C001
TM0
0250
Timer instruction
TM0
Timer terminal
Y00
Timer set value
(2.5 sec.)
C001
TM0
[Y00]
2.5 sec.
2.5 sec.
[Ex.]
Output instruction
(external output)
[Ex.]
C002
CN0
0003
Counter instruction
X5
C120
Counter set value
Resetting the CN0
CN0
Counter terminal
Y01
Output instruction
(external output)
C002
CN0
[Y01]
X5
[C120]
1
2
3
4
5
Timer
instructions
From the preceding page
Continued on the following page