6- 19
Installation Conditions and Method
6
6-3 Connection and installation methods of camera (IV-S20C1, IV-S30C1/
C2)
[1] Connecting and installation to the IV-S20C1
(1) Connection
Connect the cameras (up to 2 cameras), remote key pad, and monitor to the IV-S20 main housing.
Camera cable
Camera 1
Camera 2
3
Monitor connector
Monitor
Camera 2 connector
Camera 1 connector
Plug
Connector
1
1
4
IV-S20 main
housing
(side view)
1
Connect the camera cable connectors to the camera 1 (CAMERA1) and camera 2 (CAMERA2)
connectors on the IV-S20 main housing.
Note: Only connect or disconnect the camera connectors while the power is OFF.
- Push the convex side of the connector into the concave side of the mating connector. When the
connector is all the way on, it clicks.
- To disconnect the connector, hold the plug of the connector, and pull it straight out.
- A camera connected to the camera 1 connector (CAMERA1) is treated as camera 1 by this
system, and a camera connected to the camera 2 connector (CAMERA2) is treated as camera
2.
Note: You must have a camera connected to the camera 1 connector.
- The camera cable length is 3m. If you need a longer cable, order extension camera cable IV-
S20EC2 (cable length 2m) or IV-S20EC4 (cable length 4m).
Extension camera cable IV-S20EC2/4
Camera connector of
IV-S20 main housing
2
Screw and the IV-S20L16 camera lens on the lens holder of the camera body, and secure it in
place.
Lens holder
Camera lens
(
IV-S20L16, etc.
)
IV-S20C1