9-110
9
Existence inspection by point measurement
· You can switch between displaying all of the headings together and displaying each one
separately using the ESC key.
Continued from the previous page
Continued on the following page
Go to page 9·112
1
POINT SIZE :
Y-08
×
X-08(2
to
32)
2
STO PNT POSITIONS 000(0
to 255 )REG.NO
YES
3
START POINT POS MOVE(
,
)
4
BLOCK LAYOUT
001
×
001
5
BLOCK SPACING
Y-004
X-004
6
STORE BLOCK COND EXEC
7
DELETE BLOCK COND EXEC
8
UPPER MENU
[Example of a block registration]
(Binary image)
Set the starting point in items
2
and
3
above.
This value will be 127 when AV-LIGHT-
LEVEL (average light level) is selected
for the processing mode.
X
X
Y
Menu
Setting details
Set the size of the point (vertical and horizontal), within the range of
2 to 32, in units of 2 pixels.
1
POINT SIZE
2
STO POSITIONS
3
START POINT POS
Set the number of vertical objects times the number of horizontal
objects that will be registered as a block.
Set the vertical and horizontal intervals for points in the objects that
will be registered as a block, in unit of 1 pixel. (Min. 0 pixel.)
Store the settings as a block.
Delete all of the registered points in a block.
Returns you to the [MEASURING COND] (measurement condition)
menu.
4
BLOCK LAYOUT
5
BLOCK
SPACING
6
STORE BLOCK COND
7
DELETE BLOCK COND
8
PRIOR MENU
Set the starting point position.
· A group of pixels used as a point are treated as a single pixel.
· The point identifying a block is the starting point.
Set points individually, and select NO/YES to store each.
· There are a maximum of 256 point registration locations (0 to 255)
for the BIN-CONV (binary) mode and 128 point registration locations
(0 to 127) for the AV-LIGHT-LEVEL (average light level) mode.
· The point identifying a block of pixels is the starting point.
Enter 002 (vertical)
×
003 (horizontal) in item
4
BLOCK LAYOUT,
and enter the vertital (Y) and horizontal (X) intervals in item
5
BLOCK SPACING. Then select item
6
STORE BLOCK COND
to store the settings for the block.
When BIN-CONV (binary) is selected
as the processing mode.
When AV-LIGHT-LEVEL
(average light level) is selected as the
processing mode.
Return to the [MEASURING COND] (measurement condition) menu, and select item
5
UPPER MENU
Item
7