6-5
Installation Conditions and Method
6
2
2
2
2
2
Considering the focal length
The actual focal length, 16.5 mm, is longer than the lens focal length, f = 16 mm, by 0.5 mm.
However, if the camera installation distance of 500 mm is within the focal range (distance from
an object) of the actual lens (f = 16 mm), you can use it.
1. The focus range of the IV-S20L16 camera lens (f = 16 mm) built into the IV-S20 is from 50
mm to infinity. Therefore, the camera installation distance of 500 mm is within the focal
range, and the IV-S20L16 lens can be used.
2. When another lens (with a focal range of 16 mm) is used, if its focal range exceeds 500 mm,
install a commercially available C mount close-up shot ring. Use a ring that is 0.5 mm thick
(16.5 - 16 = 0.5 mm).
3
3
3
3
3
Resolution
When the displayed image fills the whole monitor screen, and the view (in the horizontal
direction) is 114.6 mm wide, the resolution is 223.9
µ
m.
See "Glossary" for the diefinition of resolution.
114.6mm
512(pixelcount)
223.9
µ
m
400
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
500
600
700
Wave length
[
nm]
Relative response
800
900
1000
The spectral sensitivity characteristics of the CCD element used in the CCD camera are listed
below.
- Spectral sensitivity characteristics of the CCD element
Notes
- The values shown in the tables on page 6-5 and 6-6 are only reference data for installation.
These values may vary, according to the characteristics of lenses you are using. When using
any lens, check the data using the actual equipment.
- If you want to use a camera lens other than the IV-S20L16, buy a lens with a C type lens base.
(The IV-S20L16 has a C type lens base.)
- A lens with too short focal length (f = 4.2 mm or 8 mm) will distort the edges of the field of view.