Distance and angle measurement
9-59
9
Go to page 9·6
Continued on the following page
Go to page 9·61
Select item
6
MEAS.PROG.COND (conditions for measurement programs).
When the GRAV (center of gravity) is selected
[TYPE00-MEAS1]
1
MEAS SELECTION NO
CHECK-DEG-OF-MATCH
DST&AGL MES. (GRAY&EDGE GRAV)
INSPECT-LEAD MEASR-BIN-AREA
CNT-BIN-OBJ LABEL-BIN-OBJ
POINT MEAS
2
COMPARE IMAGES NO YES(CAM1)
3
SELECT CAMERA CAM1
CAM2
4
COPY
EXEC
←
TYPE00
−
MEAS1
−
NO
5
INITIALIZATION
EXEC
6
MEAS.PROG. COND (TO NEXT SUB-MENU)
7
EVALUATION COND (TO NEXT SUB-MENU)
8
NUMERIC CALC COND (TO NEXT SUB-MENU)
9
OUTPUT CONDITIONS (TO NEXT SUB-MENU)
0
UPPER MENU
This is how the display looks when GRAY&EDGE are selected
Select item
3
START POINT COND (conditions for the starting point)
[MEASURING COND] (TYPE00-MEAS.1-DST&ANGL.MEAS)
1
START POINT NO 00(0~15) REG.NO YES
2
START POINT MODE GRAY-SEARCH
EDGE-DETECT
3
START POINT COND (TO NEXT SUB-MENU)
4
AUX.CONDITIONS (TO NEXT SUB-MENU)
5
DISTANCE COND (TO NEXT SUB-MENU)
6
ANGLE CONDITIONS (TO NEXT SUB-MENU)
7
UPPER MENU
If item
1
START POINT NO is set to YES (enable registration), then items
2
to
6
will be displayed.
On the MAIN OPS MENU, move the cursor to SET-SCRN, and press SET key.
-
On the [SYSTEM SETUP], move the cursor to item
2
OBJECT TYPE COND and press SET key.
-
Select item
0
MEASUREMENT 1,
q
MEASUREMENT 2 or
w
MEASUREMENT 3 on the
[OBJECT TYPE COND] (conditions for object types) menu.
This is how the line looks when
the object type is set to 00 and
the selected measurement is 1.
· Set the DST&AGL MES. (measurement of distance and angle) which can be found under item
1
MEAS SELECTION (select measurements) to either GRAY&EDGE (gray scale search and
edge detection) or GRAV. (center of gravity).
· Item
2
COMPARE IMAGES (calculation between images) will be displayed unless NO is
selected in item
8
NUMERIC CALC COND(camera selection) which is in the [OBJECT TYPE
COND] menu.
Select the GRAY-SEARCH
(gray scale search) for starting point mode
Select the EDGE DETECT
(edge detection) for starting point mode
Measurement conditions
1
START POINT NO
2
START POINT MODE
(starting point mode)
3
START POINT COND
(start point condition)
4
AUX.CONDITIONS (auxiliary condition)
5
DISTANCE COND (distance condition)
6
ANGLE CONDITIONS (angular condition)
7
UPPER MENU
Setting details
Set the starting point number to any number from 0 to 15 and
then set REG.
(registration)
to YES, to save your selection.
Select either GRAY-SEARCH (gray scale search) or EDGE
DETECT (edge detection) as the starting point mode.
These are set in the next menu.
This will return you to the [TYPE00-MEAS1 to 3] menu.
[2] Setting details
An explanation of item
6
MEAS.PROG.COND (conditions for measurement programs) from the
[TYPE00-MEAS1 to 3] menu.