10-4
PC Function
10
(2) Ladder circuit creation 1 (setting input signals)
1. Move the cursor to item
2
SET POSITION with the up and down keys, and press the SET key.
- The ladder circuit cursor can be moved with the up, down, left and right keys. Move the cursor
to a position where an input terminal will be placed, and press the SET key.
2. Move the cursor to item
3
INPUT SIGNAL with the up and down keys, and press the SET
key.
- In the case of the positional deviation measurement, degree of match inspection, lead
inspection, object counting by binary conversion or label measurement by binary conversion,
first move the cursor to REGT.NO. (register number) with the left and right keys, and select a
number with the up and down keys. This registration number should be the same registration
number specified on the [EVALUATION COND] menu.
Positional deviation measurement: 0 to 7 Degree of match inspection: 0 to 15
Lead inspection: 0 to 3 Object counting by binary conversion: 0 to 3
Label measurement by binary conversion: 0 to 3
3. After moving the cursor to the kind of input signal you want with the left and right keys, select a
number with the up and down keys. Then press the ESC key. (See page 10-6 for the kinds of
input signals available for each measurement program, and see page 10-7 for details about the
auxiliary relays.)
4. Move the cursor to item
4
LOGICAL SYMBOL with the up and down keys, and press the
SET key.
5. Move the cursor to the logic symbol to be used for the input signal selected in step 3, and press
the SET key.
-
The logic symbols and the input signals will be displayed as a ladder circuit.
Display example:
Logic symbol
Function
Deletes a contact on the cursor. (Contacts after the deleted contact will not be
brought forward.)
Note: This symbol cannot be used on the first row.
Deletes the contact on the cursor. (Contacts after the deleted contact will be
brought forward.)
When a contact exists only on the first row, if the contact is deleted, also the
output relay will be deleted.
a contact on a series circuit (ON, when the evaluation result is OK)
b contact on a series circuit (OFF, when the evaluation result is OK)
Used to create an OR circuit.
Used to create an OR circuit
Deletion
2
1
3
5
4
[OUTPUT CONDITIONS]
(TYPE00-MEAS.0
-
POS-DEVIATION)
1
PAGE NO.
0(0~4) REG.NO YES
2
SET POSITION
MOVE
3
INPUT SIGNAL
REGT.NO.00(0~
7
)
MATCH M0(0~1) CRD.X0(0~1) CRD.Y0(0~1)
DEVIAT-x0(0~1) DEVIAT-y0(0~1) AGL-DV B
CAL N00(0~15) AUXRLY C000(0~127)
4
LOGICAL SYMBOL
DEL.
5
OUTPUT SIGNAL
AUX.RLYC000(0~127) DEL.
6
UPPER MENU
[PAGE0]
INPUT0
LOGIC
INPUT1
LOGIC
INPUT2
LOGIC
INPUT3
LOGIC
1
0
2
3
4
5
6
7
OUT
Ladder circuit
cursor
Continued on the following page
From the preceding
page
0M0
0
1
2
3
4
5
6
7
OUT
[PAGE0]
INPUT0
LOGIC