Lists of function parameters
38
Paramete
r
Name
Setting Range and Description
Factory
settings
Mod
ificat
ion
Page
F2-21
V/F Voltage V1
0.0%—F2-19;
F2-13 is taken as 100%
0.0%
×
93
F3. Motor Parameters
Parameter
Name
Setting Range and Description
Factory
settings
Mod
ificat
ion
Page
F3-00
Rated Power
0.40—500.00kW
Depend on
inverter
model No.
×
94
F3-01
Number of Poles
2—48
4
×
94
F3-02
Rated Current
0.5—1200.0A
Depend on
inverter
model No.
×
94
F3-03
Rated Frequency
1.00—650.00Hz
50.00Hz
×
94
F3-04
Rated Rotation Speed
125—40000r/min
Depend on
inverter
model No.
×
94
F4: Digital Input Terminals and Multi-Speed
Paramete
r
Name
Setting Range and Description
Factory
settings
Mod
ificat
ion
Page
F4-00
Functions of Digital
Input Terminal X1
1
F4-01
Functions of Digital
Input Terminal X2
2
F4-02
Functions of Digital
Input Terminal X3
3
F4-03
Functions of Digital
Input Terminal X4
12
F4-04
Functions of Digital
Input Terminal X5
13
F4-05
Functions of Digital
Input Terminal
X6/PFI/Pulse
Frequency Input
0
F4-06
Functions of Digital
Input Terminal X7
(Extension Terminal)
0: Connection to the
following signals is
inapplicable
±1: Multi-band
frequency
option 1
±2: Multi-band
frequency
option 2
±3: Multi-band
frequency option 3
±4: Check of upper
water level
limit of clean water
pool
±5: Check of lower
water level
limit of
clean water pool
±6: Check of water
shortage level of clean
±31: Check of
Contactor 5K2
±32: Auxiliary setting
channel disabled
±33: Switching of PID
settings to AI2
±34: Shutdown
DC-braking
±35: PID (Process
identification)
disabled
±36: PID Parameter 2
Option
±37: Three-wire mode
shutdown
command
±38: Internal virtual
FWD terminal
±39: Internal virtual
REV terminal
±40: Retention of
0
× 95