Lists of function parameters
58
FC: Keyboard Operation and Display Settings
Paramete
r
Name
Setting Range and Description
Factory
settings
Mod
ificat
ion
Page
FC-00
Display Parameter
Options
0: All parameters 1: User parameters 2:
Those different from factory settings
0
○
156
FC-01
Key Functions and Auto
Lock
Units digit: Auto key lock
0: Unlocked 1: All locked
2: All locked except
3: All locked
except
4: All locked except
and
5: All loced except
and
Tens digit: Function options for
:
0: Effective only when the command
execution channel is the control panel
1: Effective when the command execution
channel is the control panel, terminal or
communication port; the system is shut
down in the shutdown mode
2: When the control panel is the command
execution channel, the system can be
shut down in the shutdown mode; If a
free shutdown is executed when the
command execution channel is not the
control panel, Er.Abb will be reported
Hundreds digit: Function options for
(applicable only to panel command
channels):
0: Ineffective 1: Only effective in
standby mode
2: Effective in both standby mode and
operation mode
Thousands digit: Function options for
(applicable only to panel command channels)
0: Operation
1: Jog
0000 ×
156
FC-02
Monitoring Parameter
Option 1
1
○
157
FC-03
Monitoring Parameter 2
-
1
○
157
FC-04
Monitoring Parameter 3
-1
~
50
-1 means void; 0
~
50 mean FU-00
~
FU-50
which are used to select monitoring parameters
displayed in both operation monitoring mode
and standby monitoring mode
-
1
○
157
FC-05
Monitoring Parameter 4
-
1
○
157
FC-06
Monitoring Parameter 5
-
1
○
157
FC-07
Monitoring Parameter 6
-
1
○
157
FC-08
Monitoring Parameter 7
1
~
50
-1 means void; 0
~
50 mean FU-00
~
FU-50
which are used to select monitoring parameters
displayed in both operation monitoring mode
and standby monitoring mode
-
1
○
157