![Senlan SB200 Series Скачать руководство пользователя страница 106](http://html1.mh-extra.com/html/senlan/sb200-series/sb200-series_user-manual_1239807106.webp)
Details about Function Parameters
102
%
10V/20mA V/mA
100%
(F6-01,F6-03)
(F6-00,F6-02)
F6-06
F6-04
F6-00 = 0.00
F6-01
=
100.00
F6-02
=
0.00
F6-03
=
100.00
F6-04
=
30.00
F6-05
=
0.00
F6-06
=
20.00
0
Min. Input Analog Quantity
Max. Input Analog Quantity
Settings/feedback value corresponding with min. input analog quantity
Settings/feedback value corresponding with max. input analog quantity
Input Analog Quantity of Inflection Point
Deviation from inflection point
Settings/feedback value corresponding with inflection point
Analog Input Example 8 (Application with inflection point):
In some applications where the analog input voltage is 0
~
10V/0
~
20mA (split into two slope rates),
the parameter settings will be as follows:
All settings of AI2 and AI3 are identical to those of AI1.
“Filter time”: If the filter time is increased, the response will be slower, but the anti-interference
performance will be better; if the filter time is decreased, the response will be faster, but the
anti-interference performance will be poorer.
“Offline threshold”: When the analog input falls below the offline threshold, it is considered as
an offline. An offline is confirmed by Fb-09 “Analog Input Offline Action”.
NOTE
: If there are both positive and negative input signals, it’s impossible to judge whether there is an
offline. If the offline threshold is set as 0, no offline judgment will be needed.
F6-27
AO1 Function Options
Factory
Settings
0
Modification
○
Setting
Range
Refer to the following table of definitions of analog input
F6-28
AO1 Type Options
Factory
Settings
0
Modification
○
Setting
Range
0: 0
~
10V or 0
~
20mA 1:
2
~
10V or 4
~
20mA
2: 5V or 10mA is taken as the
center
F6-29
AO1 Gain
Factory
Settings
100.0
%
Modification
○
Setting
Range
0.0
~
1000.0
%
F6-30
AO1 Offset
Factory
Settings
0.00%
Modification
○
Setting
Range
-
100.00
~
100.00
%
; 10V or 20mA is taken as 100
%
%
10V/20mA
V/mA
100%
(F6-01,F6-03)
(F6-00,F6-02)
F6-06
F6-04
F6-05
F6-00 = 0.00
F6-01 = 100.00
F6-02 = 0.00
F6-03 = 100.00
F6-04 = 30.00
F6-05 = 5.00
F6-06 = 20.00
0
Min. Input Analog Quantity
Max. Input Analog Quantity
Settings/feedback value corresponding with min. input analog quantity
Settings/feedback value corresponding with max. input analog quantity
Input Analog Quantity of Inflection Point
Deviation from inflection point
Settings/feedback value corresponding with inflection point