Details about Function Parameters
71
F1-06
Jog Frequency
Factory
Setting
s
5.00Hz
Modification
○
Setting
Range
0.10
~
50.00Hz
F1-07
Jog Acceleration Time
Factory
Setting
s
Depend
on
inverter
model
No.
Modification
○
F1-08
Jog Deceleration Time
Factory
Setting
s
Depend
on
inverter
model
No.
Modification
○
Setting
Range
0.1
~
60.0s
NOTE: Factory settings for jog acceleration/deceleration time are 6.0s for 22kW
inverter series and below
Factory settings for jog acceleration/deceleration time are 20.0s for 30kW inverter
series and above
In the panel control mode, set the thousands digit of FC-01 as 1 and
will be used for the jog;
in the terminal control, standby mode, jogging will be enabled by Digital Inputs 14 “Clockwise
Jog” and 15 “Anticlockwise Jog”. When both the signals are effective or ineffective, jog will not
be enabled.
In the jog mode, auxiliary settings and PID frequency modification are ineffective.
The start/stop mode of a jog is fixed as startup at the startup frequency and shutdown in the
deceleration mode.
F1-09
Clockwise/Anticlockwise Rotation
Deadband Time
Factory
Setting
s
0.0s
Modification
×
Setting
Range
0.0
~
3600.0s
F1-09“Clockwise/Anticlockwise Rotation Deadband Time”: This means the latency time for
switching between clockwise/anticlockwise rotations. The function used to dampen the impact of
the switching between clockwise/anticlockwise rotations on the machine.
F1-10
Startup Delay Time
Factory
Settings
0.0s
Modification
○
Setting
Range
0.0
~
3600.0s; when an operation command is received, the latency settings will be
effective in a latter time; when F8-00
≠
0, this parameter is ineffective