Inverter Operation and Trial Operation
29
4.1.2. Display Status and Operation of Control Panel
The control panel of the SB200 inverter series has the following display statuses: monitoring status
(including standby monitoring and operation monitoring), parameter editing status, and fault status,
alarm status, etc. Refer to the following drawings for how to switch between different statuses:
Monitoring status
To next level menu
To next level menu
To next level menu
1st level menu
2nd-level menu
3rd-level menu
Back to monitoring status
To previous level menu
To previous level menu
Display monitoring
parameter in a cyclic way
Modify parameter No.
Change menu Number
Select digit
to be modified
Save parameter
Increase/decrease
parameter value
Select digit
to be modified
Standby Monitoring
Press
under this status and the control panel will display different standby parameters
(defined via FC-02—FC-08) in a cycling way.
Operation Monitoring
Press
under this status and all monitoring parameters (defined via FC-02—FC-12) will be
displayed in a cycling way.
Parameter Editing
Press
菜 单
M E N U
under the monitoring status to enter the editing status. Under the editing status, the
display will be in the form of a 3-hierarchy menu system (sequence: parameter group No.
→
Serial
No. within parameter groups
→
parameter value). Press
确 认
E N T E R
to enter inferior hierarchies level
by level and press to
菜 单
M E N U
return to the superior hierarchy (if it is the top hierarchy of the
menu, you will return to the monitoring status). Use
or
to change the parameter
group No., serial No., within parameter groups or parameter value. Use
to shift or modify
digits. Press
确 认
E N T E R
to store modified results, return to the second hierarchy and redirect to the
next parameter.