Lists of function parameters
56
Paramete
r
Name
Setting Range and Description
Factory
settings
Mod
ificat
ion
Page
Failure, Self-Reset and
Operation Suspension
Fb-26
Poweron Self-Restart
Enabled
0: Disabled
1: Enabled
1
○
152
Fb-27
Braking Unit Working
Point
620
~
720V 680V
○
152
Fb-28 Modulation
Mode
0: Auto modulation
1: Continuous modulation
0
○
153
Fb-29
Carrier Frequency
15kW and below: 1.1k
~
12.0kHz; factory
settings: 4.0kHz
18.5
~
160 kW: 1.1k
~
8.0 kHz; factory
settings: 2.5kHz
200kW and above: 1.1k
~
5.0kHz; factory
settings: 2.0kHz
Depend on
inverter
model No.
○
153
Fb-30
Random PWM Settings
0
~
30%
0%
○
153
Fb-31
Carrier Frequency Auto
Adjustment Options
0: Disabled
1: Enabled
1
○
153
Fb-32
Deadband Compensation
Enabled
0: Disabled
1: Enabled
1
×
154
Fb-33
Space Vector Angle
Shutdown Memory
0; Memory inapplicable
1: Memory
0
×
154
Fb-34
Overmodulation
Enablement
0: Disabled
1: Enabled
1
×
154
Fb-35
Cooling Fan Control
0: Auto operation
1: Uniterrupted operation
0
○
154
Fb-36
Width of Avoidance
Frequency 1
0.00
~
625.00Hz 0.00Hz
○
155
Fb-37
Avoidance Frequency 1
0.00
~
20.00Hz 0.00Hz
○
155
Fb-38
Avoidance Frequency 2
0.00
~
625.00Hz 0.00Hz
○
155
Fb-39
Width of Avoidance
Frequency 2
0.00
~
20.00Hz 0.00Hz
○
155
Fb-40
Avoidance Frequency 3
0.00
~
625.00Hz 0.00Hz
○
155
Fb-41
Width of Avoidance
Frequency 3
0.00
~
20.00Hz 0.00Hz
○
155
Fb-42
Water Level Transducer
Abnormality Options
0: No action 1: Alarm 2: Fault and free
shutdown
0
○
156