5.3 Details of external assembly procedure, Range of inside seal
diameter between d1=10 mm and d1=60 mm
Position of the item numbers
5.3.1 External assembly AM_1.1
External assembly AM_1.1, Range of inside seal diameter between d
1
=10 mm and
d
1
=60 mm
The six assembly fingers must be adjusted so that they are in the
gripper condition "CLOSED" within the seal and aligned centrically
towards the centre axis of the gripper. Depending on the ovality of
the seal, there must be a sufficient safety distance (dimension x)
between the seal and the assembly fingers.
NOTE
It must be checked whether the stroke of triple jaw A and triple
jaw B are set so that the assembly fingers of the gripper do not
overstretch the seal in the opened condition! THEREFORE: When
starting up, open up the assembly fingers of the gripper without
the seal to set the top jaws! (compressed air connection (3) and
(4) pressurised) Then, before proceeding with external assembly
AM_1.2, adjust the jaw stroke to the seal size to be assembled in
accordance with chapter „Setting the end positions“