![SCHUNK ORG 85 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/schunk/org-85/org-85_assembly-and-operating-manual_1215965038.webp)
Assembly and installation
38
03.00 | ORG | Assembly and Operating Manual | en | 389246
4.6.3 Mounting inductive proximity switch IN 30
CAUTION
Damage to the proximity switches possible!
The proximity switches can be damaged or destroyed by
incorrect settings.
•
Avoid incorrect setting of the proximity switches
•
Avoid collisions
With the inductive proximity switch IN 30, the Z-stroke and the
triple jaws A or B can be monitored
Distance between gripper finger and base jaw
Initial commissioning
of the product
■
Intermediate jaws (23) were mounted.
Ø
Mount and adjust the proximity switch.
Subsequent assembly
■
Top jaws are already mounted:
Ø
Measure distances A and B from the rear edge of the base jaws
(16) to the top jaws and note these values.
Ø
Disassemble all top jaws.
Ø
Attach intermediate jaws (23) to the base jaws with a screw (82).
The cams on the intermediate jaws must point outwards.
Ø
Mount and adjust the proximity switch.
Ø
Installing the top jaws.
Ø
Observe and adhere to noted distances A and B.