5.2 Function diagram external assembly
The following figure shows the conditions and condition changes of the
O-ring gripper for external assembly as a chart. The function diagram
uses four 3/2-way valves in the same way as in the pneumatics circuit
diagram on page 21.
Please note the additional information and comments on the function
diagram and the assembly procedure below the function diagram!
External installation process
Position/
status
No.
Denomination
Jaw triple A
3/2 way valve
3/2 way valve
Jaw triple B
on
to
3/2 way valve
Z-stroke
back
front
3/2 way valve
from control
from control
from control
from control
from control
on
to
Function diagram external assembly