Initial Operation
3
User guide
Switching off and disconnecting from the external DC supply
3.2
A
rt.
no.
: 0-48-
0227
Rev.:
g
DEFIGARD/PHYSIOGARD Touch 7
3.2 Switching off and disconnecting from the
external DC supply
3.2.1
Lock Touch screen
Lock the Touch screen
In the ON/OFF dialogue, select “ Lock touch screen”.
Unlock Touch screen
Press the
button twice. The message appears “Touch screen unlocked”
Note: If you touch the locked touch screen, a message prompts you to press the ON/
OFF button twice to unlock the screen.
3.2.2
Internal safety discharge
The
DEFIGARD
®
Touch 7
has an internal safety discharge circuit for internal
discharge of the defibrillator’s stored energy. The defibrillator displays the message
"Internal discharge" during the safety discharge.The energy is internally discharged
when
• the shock is not delivered within 20 s after charging
• a lower energy value is selected while the defibrillator is charging
• the battery voltage is insufficient
• the device is defective
• the device is turned off
Furthermore the residual energy stored in the defibrillator 100 ms after shock release
is always discharged internally.
3.2.3
Interruption of external power supply
1. Press the
on/off
button.
2. The dialogue No/
Yes
is displayed.
3. Confirm switch-off or cancel with No.
4. Remove the device from the charging station if you do not want to recharge the
battery.
The “Restart” function is used to exit the Post-Intervention or the control panel menu
directly by restarting the device instead of switching it on and off.
Forced shutdown procedure
If the device cannot be switched off via the above procedures, press and hold the
green
On/Off
button until the device is switched off.
Yes
No
Lock touch screen
Restart
Switch off device?
If the external DC supply is interrupted, the device automatically switches over to
battery operation. The user settings are maintained.