PY Manual
Copyright © 2006 SANYO DENKI
AMERICA
, Inc.
81
Name
Abbrev
Range
Default
Units
Mode-
Page
Internal Velocity,
Command Value #3
VCI3
0 to 32767
1500
min
-1
1-10
Internal Current Limit Value
IILM
30 To (IP/IR)
x 100
100 % 1-11
Sequence Current Limit Value
SILM
30 To (IP/IR)
x 100
120 % 1-12
Holding Brake Timing
THB
0 To 1000
300
mS
1-13
Velocity Command Scale
VCMS
0 To 3000
500
min
-1
/V 1-14
Torque Command Scale
TCMS
0 To 400
50
%/V
1-15
Motor Encoder Pulse Number
MENP
500 to 65535
$$$$
P/R
1-16
Full Close Encoder Pulse
Number
EENP*
500 To 65535
$$$$
P/R
1-17
Name
Abbrev
Range
Default
Units
Mode-
Page
Command Pulse Train Form
PMOD
0, 1
00000000
Bit
2-0
Amplifier Function Select #0
Func0 0,
1 00000000
Bit
2-1
Amplifier Function Select #1
Func1 0,
1 00000000
Bit
2-2
Amplifier Function Select #2
Func2 0,
1 00100000
Bit
2-3
Amplifier Function Select #3
Func3 0,
1 00000001
Bit
2-4
Amplifier Function Select #4
Func4 0,
1 00000001
Bit
2-5
Amplifier Function Select #5
Func5 0,
1 00000000
Bit
2-6
Amplifier Function Select #6
Func6 0,
1 00000000
Bit
2-7
Name
Abbrev
Range
Default
Units
Mode-Page
Position Loop, Gain
Kp
1 To 1000
45 (30)
rad/S
3-0
Velocity Loop, Proportional Gain
Kvp
10 To 3000
100 (70)
Hz
3-1
Velocity Loop, Integral Time
Constant
Tvi
1 To 1000
15 (20)
mSec
3-2
Zero Adjustment of Velocity
Command
Vzero +/-16383 $$$$
3-3
Zero Adjustment of Torque
Command
Tzero +/-16383 $$$$ 3-4
Name
Abbrev
Range
Default
Units
Mode-Page
Monitor #1 Output
M1
12 Ranges
Vm2mV/mi
n
-1
4-0
Monitor #2 Output
M2
12 Ranges
Ic2v/IR
4-1
Gain Select (older models only)
GAIN
2 Ranges
Fix
4-2
Servo Function Choice (newer
models)
Func 4
Ranges Normal 4-2
Control Mode
TYPE
6 Ranges
$$$$
4-3
Encoder Type
ENKD
3 Ranges
$$$$
4-4
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com