PY Manual
Copyright © 2006 SANYO DENKI
AMERICA
, Inc.
99
Function Switch 1
Func1
Remote Operator Mode:
2
Page:
2
Default Value:
00000000 Bit
Function:
I/O
Setting Range:
0,1
Description:
•
A desired function can be set from the digital switch
•
Bit 7 is effective in the position control mode.
•
Bit 6 is effective in both the position and velocity control modes.
•
When Bit 4 is set to “1”, the position deviation is not cleared upon the occurrence of an alarm. Therefore, be
sure to clear the deviation before clearing the alarm.
•
The current limit is enabled only after the CN1-31 pins are turned on.
7 6 5 4 3 2 1 0
Current Limit Control Method
0—Internal Setting Enabled
1—External Analog Input Enabled
Backward Revolution Current Limit Input Form
0—Selects NIL Input
1—Selects PIL Input
NIL Input Polarity
0—Negative Polarity
1—Positive Polarity
Positioning Method
0—Specify Pulse Interval
1—Specify Pulse Edge
Deviation Clear
0—Clear Deviation
1—Do Not Clear Deviation
Forced Zero (When SOFF is switched to SON)
0—Enabled
1—Disabled
Torque Compensation
0—Disabled
1—Enabled
Velocity Addition Input
0—Disabled
1—Enabled
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com