PY Manual
Copyright © 2006 SANYO DENKI
AMERICA
, Inc.
33
Input Power
The table below shows the power supply capacity requirements for each of the systems.
Table 9: Power Supply Capacity Requirement
Bus Circuit
Control Circuit
Drive
Model
Motor Model
Capacity
KVA
Capacity
(A)
In Rush §
@600mS
Capacity
VA
Capacity
(A)
In Rush §
@1mS
PY2A015
P30B04010D 0.3kVA
2.1A 18A
40VA
0.2A 40A
PY2A015 P50N05020D
0.8kVA TBA
18A 40VA 0.2A
40A
PY2A030
P30B06040D 1.0kVA
6.6A 18A
40VA
0.2A 40A
PY2A030
P30B08075D 1.7kVA
9.5A 18A
40VA
0.2A 40A
PY2A050
P50N08100D 2.5kVA
5.5A 18A
40VA
0.2A 40A
PY2A050
P60B13150H 2.5kVA
7.3A 18A
40VA
0.2A 40A
PY2A050
P20B10150D 3.0kVA
8.7A 18A
40VA
0.2A 40A
PY0A015
P30B04010D 0.3kVA
1.2A 18A
40VA
0.2A 40A
PY0A015
P50N05020D 0.8kVA
3.0A 18A
40VA
0.2A 40A
PY0A030
P30B06040D 1.0kVA
3.8A 18A
40VA
0.2A 40A
PY0A030
P30B08075D 1.7kVA
5.5A 18A
40VA
0.2A 40A
PY0A050
P50N08100D 2.5kVA
7.3A 18A
40VA
0.2A 40A
PY0A050
P60B13150H 2.5kVA
7.3A 18A
40VA
0.2A 40A
PY0A050
P20B10150D 3.0kVA
8.7A 18A
40VA
0.2A 40A
PY0A100 P20B10250D
4.2kVA 12.2A
18A 40VA 0.2A
40A
PY0A100 P20B13300D
5.0kVA 14.5A
18A 40VA 0.2A
40A
PY0A150 P20B13500D
8.3kVA 24.0A
18A 40VA 0.2A
40A
§ Zero to peak currents, not RMS current.
Leakage Current
The servomotor is driven under the PWM control of an IGBT inverter in the amplifier.
This produces a high-frequency leakage current, which flows through the floating
capacitance of the motor winding, power cable and amplifier. This leakage current can
cause the malfunction of leakage detection circuit breakers or protective relays installed
on the power line.
Table 10: System Leakage Current
Motor Model
Leakage Current per Motor
P20B 3.0mA
P30B 3.0mA
P50N 3.0mA
P60B 3.0mA
1.
When using two or more motors, add the leakage current of each motor to determine the system
leakage current.
2.
The table above assumes 2m cables. The leakage current will increase with longer cables and
decrease with shorter cables.