Function Switch 6
Func6
Remote Operator Mode:
2
Page:
7
Default Value:
00000000 Bit
Function:
I/O
Setting Range:
0,1
Description:
•
This parameter is used for changing the contents of parameters or permiting execution of the test mode.
Par amet er Set up St at us
0
Set
1
Not Set
1
0
7
6
5
4
3
2
1
Enabled
0
0
1
Alarm Disabled
1
Permitt ed
Not Permitt ed
0
P- PI A ut o Sw it chi ng F unct i o n
T est M o d e A l ar m Set t ing
Syst em Par amet er R ew r it e
0
Disabled
1
T est M o d e Execut io n
Disabled
Enabled
Alarm Enabled
•
After operation, Bits 7 and 6 must be set at “0” again.
•
Turning “OFF” the control power returns bits 7, 6, and 4 back to “0”.
•
If Bit 0 is set to “1”, and alarm (memory error) will be indicated. After the necessary parameter setting
is completed, set Bit 0 to “0”, then turn power “ON”.