PY Manual
Copyright © 2006 SANYO DENKI
AMERICA
, Inc.
113
Regenerative RGKD
Remote Operator Mode:
4
Page:
9
Default Value:
Built in R
Function:
Setting Range:
Built in R
None/ Ext. R
Description:
•
Selects regenerative resistor to use.
Setting
Description
None/ Ext. R
Regenerative resistor is not connected, or
external regenerative resistor is used.
Built in R
Built in regenerative resistor is used.
•
It is important that the resistor type be set correctly. Overload protection is adjusted based on this setting.
Failure to correctly set this value can cause damage to the amplifier.
Position Loop Gain #2
Kp2
Remote Operator Mode:
8
Page:
0
Default Value:
45 (30) rad/S
Function:
Setting Range:
1 to 1000 rad/S
Description:
•
Proportional gain of the position controller
•
Enabled during gain switching