Install the amplifier vertically as shown in the figure below, with the indicated
clearances. Because the amplifier uses convection cooling it may not be mounted
horizontally. Provide the indicated space above, below and to the side of the amplifier
for airflow. If this space cannot be provided, install a fan to increase airflow around the
amplifier. At least 10 mm space should be provided on each side of the amplifier to
allow air flow.
A
B
C
D
PY2A015
160 mm
NA
25 mm
NA
PY2A030
160 mm
NA
25 mm
NA
PY2A050
160 mm
NA
50 mm
NA
PY0A015
225 mm
NA
25 mm
NA
PY0A030
225 mm
NA
25 mm
NA
PY0A050
225 mm
>197 mm
50 mm
>67 mm
PY0A100
225 mm
>197 mm
50 mm
>92 mm
PY0A150
225 mm
>197 mm
75 mm
>142 mm
Only the PY0A050, PY0A100, and PY0A150 are equipped with the “cooling fins”.
Mounting and
Clearance
Requirements
50 mm or more
50 mm or more
Back Surface
Mounting
4-M5
A
C
Cut-out
for
Cooling
Fins
D
B
Cooling
Air Flow
90 mm
or more
Fins