Output Pulse Divide Ratio
ENCR
Remote Operator Mode:
1
Page:
4
Default Value:
1/1
Function:
Monitor
Setting Range:
1 to 1/8192
Description:
•
Defines the ratio of encoder pulses (CN2) to control feedback pulses.
F in
Frequency in from the motor encoder
F out
Frequency out to a position controller
α
= 1 to 64 or 8192
ENCR
β
α
β
= 1 (when
α
=1 to 64)
= 2 (when
α
=3 to 64)
= 1 to 8191 (when
α
= 8192)
F out F in
β
α
.