PY Manual
Copyright © 2006 SANYO DENKI
AMERICA
, Inc.
44
Pin TB Pos
Abbrev.
Description
Circuit
Type
SPE
—Speed Matching. When the velocity command
and velocity feedback is smaller than the specified
value, this signal goes to low impedance.
INP
—In Position (Position Mode). This signal
indicates that the content of the deviation counter is
within the setting range, OVF. OVF many be set using
the Remote Operator (Mode 1, Page 1).
CMD
—Command Accept Permit
41 10 SRDY
Start Ready Complete. This signal comes ON and goes
to low impedance after the bus power (R, S, and T) is
applied to signify readiness to receive the Servo “ON”
(SON) signal.
6
42 32 HBON
Holding Brake. This output is used to control the
holding brake relay.
6
43 27 ALM1
Alarm Output 1. Alarm output 1 may be set to indicate
any alarm (Alarm bit) or to be the least significant bit of
a four-bit alarm code. This choice is made using the
Remote Operator to set Func2 bit 6 (Mode 2, page 3).
The default is Alarm Code Output.
6
44
26
ALM2 Alarm Output 2 see ALM1
6
45
25
ALM4 Alarm Output 3 see ALM1
6
46
24
ALM8 Alarm Output 8 see ALM1
6
47 9 SG Signal Ground for forward revolution pulse command
pins 26 and 27.
N/A
48 46 SG Signal Ground for reverse revolution pulse command
pins 28 and 29.
N/A
49 29
12-24
VDC Output Sequence Power Supply. External power supply
for CN1-39, 40, 41, 42, 43, 44, 45, and 46. Use only
pins 38 or 49, NOT BOTH.
N/A
50 35
12-24
VDC Input sequence power supply 2. External power for
CN1-34 and CN1-35.
N/A