![Sanyo Denki PY Series Скачать руководство пользователя страница 122](http://html.mh-extra.com/html/sanyo-denki/py-series/py-series_installation-and-operation-manual_1198373122.webp)
PY Manual
Copyright © 2006 SANYO DENKI
AMERICA
, Inc.
121
Overvoltage
Symbol
7-Segment Display
Alarm code
CN1- [46,45,44,43]
OV
5
0101
Operating Condition
Cause
Corrective Action
Alarm occurs when the
control power supply is
turned ON
•
Faulty PC board
•
Replace servo
amplifier
Alarm occurs after the bus
power (R, S, and T) supply
is turned ON for a while
•
The input power
voltage is high
(high-line)
•
The input power
waveform is distorted
•
Lower the line voltage
below the specification
Alarm occurs while the
motor is in operation
•
The load inertia is too
large for the existing
regeneration resistor
•
Lower the load inertia
•
Add or increase the
size of the external
regen resistor.
Overspeed
Symbol
7-Segment Display
Alarm code
CN1- [46,45,44,43]
OS
6
0110
Operating Condition
Cause
Corrective Action
•
Faulty PC board
•
Replace servo
amplifier
Alarm occurs when the
control power supply is
turned ON
•
Faulty motor encoder
•
Replace servo motor
•
Improper velocity scale
setting
•
Reset the velocity scale
•
The velocity command
is too high
•
Reduce the command
below the system
specification
•
Incorrect encoder
wiring
•
Correct encoder wiring
Alarm occurs while the
motor is in operation
•
Faulty encoder
•
Replace servo motor
Alarm occurs when the
motor starts
•
Velocity overshoot is
excessive
•
Reset servo tuning
•
Increase the
acceleration time
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com