PY Manual
Copyright © 2006 SANYO DENKI
AMERICA
, Inc.
18
The amplifier should be installed in an environment that meets these requirements.
Table 3: Amplifier Environmental Requirements
Item
Specification
Ambient Temperature
Operating
Non-operating
0 to 55C
32° to 131°F
-20 to 65C
-4° to 149°F
Humidity Maximum
90% Non-condensing
Vibration Maximum
0.5G 10 to 55Hz
Shock Maximum
2G
Air Quality
Dust-free
Oil-free
Non-corrosive
Non-combustible
Non-explosive
During operation, the amplifier dissipates power that results in cabinet heating. The
following table lists power dissipation values for valid system configurations. These
values assume continuous rated load operation. Calculate the cabinet cooling
requirements using the power dissipation information and the formulas that follow.
Table 4: Power Dissipation
Power Dissipation [W]
Drive Model
Motor Model
Total
PCB
Heatsink
PY2A015 P30B04010D 19
-
-
PY2A015 P50N05020D 23
-
-
PY2A030 P30B06040D 32
-
-
PY2A030 P30B08075D 45
-
-
PY2A050 P50N08100D 54
-
-
PY2A050 P20B10150D 85
55
30
PY2A050 P60B13150H 85
50
50
PY0A015 P30B04010D 19
-
-
PY0A015 P50N05020D 23
-
-
PY0A030 P30B06040D 32
-
-
PY0A030 P30B08075D 16
-
-
PY0A050 P50N08100D 80
50
30
PY0A050 P20B10150D 85
55
30
PY0A050 P60B13150H 85
50
50
PY0A100 P20B10250D 170
98
72
PY0A100 P20B13300D 175
103
72
PY0A150 P20B13500D 260
150
110
Power dissipation values shown in the table do not include values for the internal
regeneration resistor.
When using an external regeneration resistor, the internal resistor is disconnected.
Amplifier
Environmental
Requirements
Power Dissipation