Samsung Electronics
122
Troubleshooting
4-3-40
/
Fan motor starting error
Outdoor unit display
(FAN PBA(FAN1))
(FAN PBA(FAN2))
Judgment Method
• Startup, and then if the speed increase is not normally.
• Detected by H/W or S/W
Cause of problem
• FAN motor connection error.
• Defective FAN motor.
• Defective PBA.
1. Cause of problem
4-3 Appropriate Measures for Different Symptom (cont.)
Yes
Power Off
Replace Fan PBA
Replace Fan PBA
Check the connection wire
Replace a normal combination
Is the resistance
value between different phases of
an Motor (U
↔
V,V
↔
W,W
↔
U)
less than 10Ω?
Is the resistance
between the body of FAN Motor
and chassis MΩ?
Does the Fan motor
connection wire properly connect?
If it is Dual Fan Controller?
If the motor is two,
the combination is normal?
Replace Fan PBA
Restart
When the error is repeated,
replace the Fan Motor
Yes
Yes
Yes
Yes
Normal ccmbination
DB31-00614E, DB31-00614F
DB31-00614G, DB31-00614H
DB31-00651A, DB31-00651B
DB31-00652A, DB31-00651B
DB31-00675A, DB31-00675B
DB31-00675E, DB31-00675F
No
No
No
No
Содержание AM072BXV Series
Страница 141: ...Troubleshooting Samsung Electronics 135 4 3 Appropriate Measures for Different Symptom cont...
Страница 160: ...Samsung Electronics 154 Troubleshooting 4 4 2 Pump down operation cont 4 4 Case study for trouble shoots cont...
Страница 162: ...Samsung Electronics 156 Troubleshooting 4 4 3 Pump out operation cont 4 4 Case study for trouble shoots cont...
Страница 190: ...PBA Diagram and Parts List Samsung Electronics 184 5 8 PF8 Inv Integration J POWER 1 2 3 4 5 6 1 7 8 12 11 10 9...
Страница 192: ...PBA Diagram and Parts List Samsung Electronics 186 5 9 PF8 Inv Integration F POWER 1 2 3 4 5 6 11 10 9 12 1 7 8...
Страница 200: ...Samsung Electronics 194 Wiring Diagram This Document can not be usedwithout Samsung s authorization 6 3 AM162BXVGF AA...
Страница 201: ...Samsung Electronics 195 Wiring Diagram 6 4 AM192BXVGJ AA This Document can not be usedwithout Samsung s authorization...