Piping Diagram
Samsung Electronics
219
7-3-1 Basics (cont.)
7-3-1-2 Refrigeration Cycle
Basic Refrigeration Cycle
The following figure shows the basic refrigeration cycle.
▪
Difference between discharge temperature and high pressure saturation temperature is referred to as discharge superheat
-
ed degree.
▪
Difference between suction temperature and low pressure saturation temperature is referred to as suction superheated
degree.
▪
Difference between condenser exit temperature and high pressure saturation temperature is referred to as subcooled
degree.
Superheated degree must be calculated at the evaporator exit. This prevents wet compression. Refrigerant flow from the
evaporator must be adjusted using the expansion valve so that only superheated vapor can flow into the compressor.
7-3 Functions (cont.)
Содержание AM072BXV Series
Страница 141: ...Troubleshooting Samsung Electronics 135 4 3 Appropriate Measures for Different Symptom cont...
Страница 160: ...Samsung Electronics 154 Troubleshooting 4 4 2 Pump down operation cont 4 4 Case study for trouble shoots cont...
Страница 162: ...Samsung Electronics 156 Troubleshooting 4 4 3 Pump out operation cont 4 4 Case study for trouble shoots cont...
Страница 190: ...PBA Diagram and Parts List Samsung Electronics 184 5 8 PF8 Inv Integration J POWER 1 2 3 4 5 6 1 7 8 12 11 10 9...
Страница 192: ...PBA Diagram and Parts List Samsung Electronics 186 5 9 PF8 Inv Integration F POWER 1 2 3 4 5 6 11 10 9 12 1 7 8...
Страница 200: ...Samsung Electronics 194 Wiring Diagram This Document can not be usedwithout Samsung s authorization 6 3 AM162BXVGF AA...
Страница 201: ...Samsung Electronics 195 Wiring Diagram 6 4 AM192BXVGJ AA This Document can not be usedwithout Samsung s authorization...