Tel: 886.2.2175 2930 Email: [email protected]
www.salukitec.com
80
10
Sweep menu
The sweep time refers to the time required for the LO tuning of the spectrum analyzer within the selected frequency
interval, and directly affects the time of one test. It generally changes with the span, resolution bandwidth and video
bandwidth. In the auto mode, the minimum sweep time will be adopted by the spectrum analyzer after
measurement setting. The sweep time can be increased in the manual mode to meet specific measurement needs.
The default sweep mode is linear sweeping, while list sweeping is optional. Multiple segment can be swept
continuously. The functions of editing, saving and recalling the list are available, thus facilitating the operation.
Sweep Time
Auto Man
Sweep
Sweep Type
Continuous
Single
Sweep Once
Triggering
[Free Run]
Sweeping mode
Linear List
Edit List
Save List
Load List
>
>
>
·
[Sweep Time Auto Man]: Press [Sweep]→[Sweep Time] to adjust the sweep
time of the spectrum analyzer. Use the number keys, step keys or knob to adjust
the sweep time. If “Man” is underlined, the sweep time can be set manually. If
“Auto” is underlined, the sweep time will be automatically associated according to
the resolution bandwidth, frequency bandwidth and video bandwidth.
· [Sweep Cont Single]: Press [Sweep]→[Sweep Type] to enable the continuous
or single sweeping mode.
· [Re-sweep]: Press [Sweep]→ [Sweep Once] to sweep once again.
· [Triggering]: Press [Sweep]→ [Triggering] to select the triggering mode,
including [Free Run], [Video], [External], etc. Refer to the trigger menu for
details.
· [Sweep Mode Lin List]: Press [Sweep]→[Sweep Mode] to enable the linear or
list mode. In the linear mode, sweeping will be performed based on the linear
frequency interval, and the frequency intervals of adjacent measurement points are
the same. The list mode is optional, in which sweeping will be performed based on
the set frequency range and other parameters in the edited list.
·[Edit list]: This is optional. Press [Sweep]→[Edit List] to enable the soft menu of
list editing. You can use soft keys such as [Add Seg], [Delete Seg] and [Delete All]
to manage and edit the sweep lit. The selected segment will be in green. After
editing the segment, press [Done] and [OK] to go back to the sweep menu.
· [Save List]: This is optional. Press [Sweep]→[Save List] to save the current list
into the spectrum analyzer for future recalling.
· [Recall List]: This is optional. Press [Sweep]→[Recall List], and the list dialog
Содержание S3302A
Страница 1: ...S3302 Series Handheld Spectrum Analyzer Datasheet Saluki Technology Inc...
Страница 70: ...Tel 886 2 2175 2930 Email sales salukitec com www salukitec com 70...
Страница 125: ...Tel 886 2 2175 2930 Email sales salukitec com www salukitec com 125 Fig 7 1 FM Demodulation Analysis Results...
Страница 139: ...Tel 886 2 2175 2930 Email sales salukitec com www salukitec com 139 Fig 8 3 Schematic Diagram of List Scanner...