Tel: 886.2.2175 2930 Email: [email protected]
www.salukitec.com
113
8
Auto Save menu
Sweep Interval
Auto
Record
Sweep Span
Auto
Automatic saving
Off
On
Time Cursor
0
Restart
>
· [Sweep Interval]: Press [Auto Save]→[Sweep Interval Auto], and set the
sweeping interval. In the default mode, the trace will be in the maximum
holding state, so that all signals measured within the sweeping interval can
be recorded.
· [Sweep Span]: Press [Auto Save]→ [Sweep Span Auto]. The span time
will be the whole sweeping period. After reaching the span time, recording
will be stopped.
· [Auto Save Off On]: Press [Auto Save]→ [Auto Save Off On] to enable
or disable the “Auto Save” mode.
[Special note]: This function cannot be enabled until the span time is
set.
· [Time Cursor]: Press [Auto Save]→ [Time Cursor] to view historical
data.
[Special note]: This must be applied in the spectrogram mode.
· [Restart]: Press [Auto Save]→ [Restart Measurement] to restart
sweeping.
[Special note]: This is not available in the spectrum analyzer mode.
The time cursor function is not available in the RSSI mode.