6) Press [Sweep]→[Power Display Curr Max] and enable the maximum option. Set the maximum power of each
displayed channel.
The power cannot be set as the maximum value until the maximum holding function is enabled.
Fig. 8-1 Schematic Diagram of Channel Scanner
2
Frequency Scanner
Below is an example of the Frequency Scanner mode, mainly involving the following procedures.
1) Press [Sweep]→ [FScan] → [Start Freq], and set the center frequency of the starting channel.
2) Press [Sweep]→ [FScan]→ [Step Freq], and set the frequency step of the measured channel.
3) Press [Sweep]→ [FScan] → [Bandwidth], and set the bandwidth of the measured channel.
4) Press [Sweep]→ [FScan] → [Number of Channels], and set the number of measured channels. At most 20
channels can be measured at the same time.