7. MAINTENANCE

The MK series pumps and electric pumps can be considered free from routine maintenance. In case extraordinary maintenance is required, get in touch 
with the SAER Technical Assistance. Do not modify the product without the necessary preventive authorization.

In the event it is necessary to perform any type of maintenance, the following precautions must be observed:
- disconnect the pump motor from the electrical system;
- wait until the temperature of the liquid is such not to create a danger of burns;
- if the liquid handled by the pump is harmful for one’s health, it is indispensable to observe the following warnings:
- the operator must wear suitable individual protection devices (mask, goggles, gloves, etc.);
- the liquid must be carefully collected and disposed of with respect for current law;
- the pump must be washed inside and out, disposing of the residues as said above.

Lubricating the bearings: 

 the bearings are of the permanently lubricated type (with grease) and, therefore, need no maintenance.

Motor coupling (MK32-40-50-65): see the reference in  picture 7b
Motor substitution (MK32-40-50-65): see the reference in picture 7a and 7b
Mechanical seal substitution (MK32-40-50-65). See picture 8

8. DECOMISSIONING 

AND 

DISPOSAL

At the end of the operating life of the pump/electropump or any of its parts, it must be disposed of in observance of current regulations. This is also valid 
for the liquid contents, with particular regard if classi

fi

 ed toxic or harmful, and for packaging.

9. TROUBLESHOOTING

PROBLEMS

CAUSES

REMEDIES

The motor doesn’t start and there is no noise or vibration

No voltage in the motor cable.

Check the device and/or electric line.

The fuses are burnt out.

Replace the fuses with others of the same value.

Motor cable interrupted.

Repair or replace the cable.

Motor broken.

Replace the motor.

The motor doesn’t start and there is noise and/or vibration

The motor was incorrectly connected.

Correct the incorrect connection (see “Electrical connection”).

The condenser is broken (for single-phase motor).

Replace the condenser.

The rotating part is hindered.

Disassemble and remove the cause.

The electrical protection devices are triggered

The power supply voltage does not match that shown on the motor plate. Change voltage or motor.
A cable is grounded or has a short-circuit.

Repair or replace the cable.

The winding is grounded.

Disassemble the motor and repeat the winding or replace the motor.

Cable terminals loose.

Tighten all the terminal clamps.

The rotating part is blocked.

Disassemble and remove the cause.

Excessive amount of sand in the water.

Reduce the 

fl

 ow rate using the delivery shutter.

Density and/or viscosity of liquid too high.

Contact the manufacturer.

Insuf

fi

 cient or no 

fl

 ow rate

The pump was not correctly 

fi

 lled with liquid.

Fill the pump.

The intake pipe is narrow or has leaks.

Replace the pipe or gasket.

The foot valve is clogged.

Clean or replace the valve.

Impeller obstructed.

Disassemble and overhaul.

Head less than declared

Incorrect rotation direction.

Change the rotation direction.

Leaks in the delivery pipe.

Replace the damaged pipe or gasket.

Inside parts worn.

Disassemble and overhaul.

Air or gas in the water.

Contact the manufacturer.

The pump operates irregularly and/or vibrates.

Pump operating with head too low.

Adjust the shutter on the delivery pipe.

Mechanical parts worn.

Disassemble and overhaul.

System NPSH is insuf

fi

 cient.

Reduce the 

fl

 ow rate.

Lower the installation level.

In the event of dif

fi

 culty in identifying the cause and/or remedy, we recommend you contact our customer support department.

10. SPARE 

PARTS

Use only original spare parts. To order spare parts, refer to the catalogues or contact the SAER Technical Assistance specifying the kind of pump, the serial 
number and the year of manufacture (all these data are to be found in the identi

fi

 cation plate).

This product is free from manufacturing defects.

Содержание PMK Series

Страница 1: ...t op rateur charg d utiliser le produit ou responsable de la maintenance doit en conna tre l emplacement et doit avoir la possibilit de le consulter tout moment D Dieses Handbuch ist Bestandteil der P...

Страница 2: ...r die Ausschaltung vom Netz der elektrischen Speisung sollte der Kategorie der Ueberspannung III entsprechen PT Conectar a electrobomba com as red de alimenta ao providenciando um interruptor omnipol...

Страница 3: ...valve Valvula checadora Clapet de ressort R ckschlagventil Valvula de no retorno d Valvole di intercettazione Gate valve Compuerta Soupape de r glement Schieber Comporta f Coni di raccordo Eccentric...

Страница 4: ...Speisung mit einer einzigen Spannung mit Kondensator f r 3 und 4 kW Leistungen monof sica para alimenta o com tens o nica com condensador para pot ncias 3 e 4 kW 3 4 d monofase per alimentazione a due...

Страница 5: ...5 8a MK 32 32 R 40 40 R 50 1 2 3 8b MK 65 1 2 3...

Страница 6: ...or hora distribuidos igualmente Max mises en route l heure galement distribu s Maximale Quantit t der Anlassen pro Stende gleicherma en verteilt M ximo arranques hora distribu dos equitativamente Moto...

Страница 7: ...he pumped liquid Temperatura del liquido bombeado Temp rature du liquide pomp Temperatur des F rdermediums Temperatura do l quido bombeado T 80 C 80 C T 120 C Qmin m3 h Qmin l min Qmin m3 h Qmin l min...

Страница 8: ...tati sulla targhetta che attesta la conformit alle norme CE fig 2 Nei gruppi elettropompa si ha una targa per la parte idraulica e una per il motore nelle pompe vendute senza motore si ha solo la targ...

Страница 9: ...vibrazioni alle strutture circostanti Verificare che le fondazioni in calcestruzzo abbiano resistenza adeguata e siano conformi alle norme di pertinenza Le pompe devono essere fissate tramite i piedi...

Страница 10: ...a necessario MESSA IN FUNZIONE Dopo aver eseguito il collegamento elettrico e l adescamento mantenendo chiusa la valvola di intercettazione sulla mandata Dare corrente attendendo che la pompa raggiung...

Страница 11: ...tituire il motore Il motore non parte e si avvertono rumori e o vibrazioni Il motore collegato in modo errato Correggere qualsiasi collegamento errato vedi collegamento elettrico Il condensatore guast...

Страница 12: ...ding to EN 60034 7 The electric pump s identificative and technical datas are listed on the name plate which certify the conformity to CE norms fig 2 In case of pump and motor assembled a name plate w...

Страница 13: ...area of fixing verify the prevention of possible vibrations to the surrounding structures Check that the strength of the concrete foundations is appropriate and complies with current relevant regulati...

Страница 14: ...essary COMMISSIONING After having done the electrical connection and the priming keeping the gauge valve closed on the delivery side Feed current waiting for the pump to reach full operating speed Slo...

Страница 15: ...t start and there is noise and or vibration The motor was incorrectly connected Correct the incorrect connection see Electrical connection The condenser is broken for single phase motor Replace the co...

Страница 16: ...ectrobomba vienen en la placa que certifica la conformidad a las normas CE fig 2 En los grupos electrobomba viene una placa en la parte hidr ulica y otra placa en el motor en las bombas vendidas sin m...

Страница 17: ...rificar que el punto y la superficie de sujeci n tienen que impedir la eventual transmisi n de vibraciones a las estructuras en los alrededores Compruebe que los cimientos de hormig n tengan la resist...

Страница 18: ...re cierre en la descarga tiene que quedarse cerrada Suministrar corriente esperando a que la bomba alcance la velocidad de r gimen Abrir lentamente la v lvula de la tuber a de descarga hasta alcanzar...

Страница 19: ...a err nea Corregir cualquier conexi n err nea ver Conexi n el ctrica El condensador est averiado para motor monof sico Sustituir el condensador El componente giratorio est frenado Desmontar y eliminar...

Страница 20: ...nn s de identification et techniques de la pompe sont crits sur la targue qui atteste la conformit les normative CE fig 2 Dans les groupes de pompe lectrique il y a une targue pour la partie hydrauliq...

Страница 21: ...ventuelle de vibration aux structures environnantes Contr ler si les fondations en b ton sont d une r sistance adapt e et si elles sont conformes aux normes du secteur d utilisation Les pompes doivent...

Страница 22: ...d marrage comment indiqu dans le paragraphe mise en fonction AVERTISSEMENT L op ration d amor age doit tre r p t dans le cas de longues p riodes de inactivit et chaque fois qu il soit n cessaire MISE...

Страница 23: ...d marre pas et on entend des bruits et ou des vibrations Le moteur a t mal connect Corriger tous les d fauts de connexion voir branchement lectrique Le condensateur est en panne pour moteur monophas C...

Страница 24: ...estaetigt Abb 2 Im Fall der Elektropumpe gibt es einen Typenschild f r den hydraulischen Teil und einen anderen f r den Motor Im Fall der Pumpe die ohne Motor verkauft wird gibt es nur einen Typenschi...

Страница 25: ...verhindern koennen Ueberpruefen Sie dass die Grundlagen aus Beton eine genuegende Festigkeit haben und den Normen entsprechen Die Pumpen sollen durch die Stuerze der Grundplatte gefestigt und mit ents...

Страница 26: ...chluss und das Anfuellen erfolgt worden sind das Absperrventil an der Druckleitung geschlossen haltend Strom geben und warten bis die Pumpe die Betriebsgeschwindigkeit erreicht hat Das Ventil an der D...

Страница 27: ...en Der Motor wurde falsch angeschlossen Falsche Anschluesse korrigieren siehe Elektroanschluss Der Kondensator ist defekt fuer Einphasenmotor Kondensator auswechseln Der rotierende Teil ist gebremst A...

Страница 28: ...chapa que certifica a conformidade as normas CE fig 2 Nos grupos eletrobomba as mismas levan umas indica is hidraulicas e uma para los motores nas bombas vendidas sem motor levam os datos hidraulicos...

Страница 29: ...m impedam eventualmente transmiss o de vibra o as estruturas circunstante Verifique se o espa o ao redor seja suficiente para garantir a ventila o e dar a possibilidade de movimento para as eventuais...

Страница 30: ...esecutar a cone o eletrica e a aspira o dejando fechada a valvula de intercep o sob a vaz o Ligue a corrente esperando que a bomba atinja a velocidade de funcionamento normal Abra lentamente a v lvula...

Страница 31: ...bra es O motor foi conectado de maneira errada Corrija qualquer conex o errada veja Conex o el ctrica O condensador est engui ado para motor monof sico Substitua o condensador A pe a rotat ria est tra...

Страница 32: ...1 4301 AISI 316 1 4401 EN GJL 250 G20Mn5 AISI 316 1 4408 MK 50 65 EN GJL 250 G20Mn5 AISI 316 1 4408 MK 80 EN 1092 MK32 MK40 PN 15 TAB I TAB II IP55 F 50 1 220 240 4 3 220 240 380 415 4 380 415V 660 72...

Страница 33: ...33 5 SAER 40 C 40 C 1000 PMK 1000 3 1 5 6 7 NPSH NPSH TAB VI NPSH II PN II 3 4 2 3 1 5 2 3 3 5 DN DN DN mm DN mm 32 50 65 100 40 65 80 125 50 80 100 150...

Страница 34: ...34 5 30 6 0 03 A 4 90 6 i ii iii iv v vi i ii iii iv v vi 30 30 40 C 90 C 55 C 50 c 10...

Страница 35: ...35 7 SAER SAER MK32 40 50 65 7b MK32 40 50 65 7a 7b MK32 40 50 65 8 8 9 NPSH 10 SAER...

Страница 36: ...pompes multi tage pour l l vation d eau claire s rie PMK PMKX sont conformes aux directive Directive Machines 2006 42 CEE Directive Compatibilit lectromagn tique 2004 108 CEE KONFORMITAETSERKLARUNG D...

Страница 37: ...37 PMK 32 PMK 32R PMK 40 PMK 40R MK40 MK40 R...

Страница 38: ...38 PMK 50...

Страница 39: ...39 PMK 65...

Страница 40: ...nual Saer se reserva el derecho de modificar los datos indicados en este manual sin previo aviso Saer se r serve le droit de modifier sans pr avis les donn es techniques dans ce manel Das Unternehmen...

Отзывы: